SECTION 1 - SPECIFICATIONS
31215031
1-23
Metric Fastener Torque Chart (Continued)
Values for Magni Coated Fasteners (Ref 4150701)*
CLASS 8.8 METRIC (HEX/SOCKET HEAD) BOLTS CLASS 8 METRIC NUTS
Size
Pitch
Tensile
Stress Area
Clamp Load
See Note 4
Torque
(Dry or Loctite® 263
™
)
K=0.17
Torque
(Lube or Loctite® 242
™
or
271
™
or
Vibra-TITE
™
111 or 140)
K=0.16
Torque
(Loctite® 262
™
or
Vibra-TITE
™
131)
K=0.15
Sq mm
KN
[N.m]
[N.m]
[N.m]
3
0.5
5.03
2.19
1.1
1.1
1.0
3.5
0.6
6.78
2.95
1.8
1.7
1.5
4
0.7
8.78
3.82
2.6
2.4
2.3
5
0.8
14.20
6.18
5.3
4.9
4.6
6
1
20.10
8.74
9
8.4
7.9
7
1
28.90
12.6
15
14
13
8
1.25
36.60
15.9
22
20
19
10
1.5
58.00
25.2
43
40
38
12
1.75
84.30
36.7
75
70
66
14
2
115
50.0
119
110
105
16
2
157
68.3
186
175
165
18
2.5
192
83.5
256
240
225
20
2.5
245
106.5
362
340
320
22
2.5
303
132.0
494
465
435
24
3
353
153.5
627
590
555
27
3
459
199.5
916
860
810
30
3.5
561
244.0
1245
1170
1100
33
3.5
694
302.0
1694
1595
1495
36
4
817
355.5
2176
2050
1920
42
4.5
1120
487.0
3477
3275
3070
NOTES:
1. THESE TORQUE VALUES DO NOT APPLY TO CADMIUM PLATED FASTENERS
5000059K
2. ALL TORQUE VALUES ARE STATIC TORQUE MEASURED PER STANDARD AUDIT METHODS TOLERANCE = ±10%
3. * ASSEMBLY USES HARDENED WASHER
4. CLAMP LOAD LISTED FOR SHCS IS SAME AS GRADE 8 OR CLASS 10.9 AND DOES NOT REPRESENT FULL STRENGTH CAPABILITY OF SHCS.
IF HIGHER LOAD IS REQUIRED, ADDITIONAL TESTING IS REQUIRED.
Go
to
Discount-Equipment.com
to
order
your
parts