SECTION 3 - CHASSIS & TURNTABLE
31215031
3-101
523612
12
623
555
ECU reported internal software error.
Error in the check of the shut-off path test of the
under- voltage detection (ECU internal
error). Diagnostic fault check to report the error
in under-voltage monitoring.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
523612
12
624
555
ECU reported internal software error.
Error in the check of the shut-off path of the
monitoring module (ECU internal error).
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
523612
12
625
555
ECU reported internal software error.
Time out error trying to set or cancelling the
alarm task (ECU internal error). Failure
setting the alarm task period.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
523612
12
627
555
ECU reported internal software error.
Error in time monitoring of the shut-off path
test (ECU internal error). Diagnostic fault
check to report the timeout in the shut
off path test.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
523612
12
628
555
ECU reported internal software error.
Error in the check of the shut-off path test of the
over voltage detection (ECU internal
error). Diagnostic fault check to report the error
in overvoltage monitoring.
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
523612
12
637
555
Internal ECU monitoring detection reported
error.
Error in the plausibility of current energizing
time with maximum permitted energizing
time. Diagnostic fault check to report the error
due to Over Run
Threshold for error detection is an internal ECU
threshold.
If error is still present, exchange ECU.
523612
14
973
5-5-5
Software reset CPU SWReset_0.
Visibility of Software resets in DSM.
Threshold for error detection is an internal ECU
threshold.
523612
14
974
5-5-5
Software reset CPU SWReset_1.
Visibility of Software resets in DSM.
Threshold for error detection is an internal ECU
threshold.
523612
14
975
5-5-5
Software reset CPU SWReset_2.
Visibility of Software Resets in DSM.
Threshold for error detection is an internal ECU
threshold.
If possible the software update has to be done.
Replace the ECU.
523612
12
1170
5-5-5
Internal software error ECU.
Error during positive test (ECU internal error).
Diagnostic fault check to report that the
positive test failed.
Threshold for error detection is an internal ECU
threshold.
Reflash ECU. If error is still active replace ECU.
523613
0
856
1-3-4
Rail pressure below setpoint, speed-depen-
dent threshold exceeded.
Rail pressure too low.
Threshold for error detection is an internal ECU
threshold.
(A) Check for leakage.
(B) Check fuel-primary pressure.
(C) Change components, check sensor and if
necessary replace it, check fuel system
and if necessary repair it.
523613
0
857
1-3-4
Rail pressure below setpoint, threshold
exceeded.
Rail pressure too low.
Threshold for error detection is an internal ECU
threshold.
(A) Check for leakage.
(B) Check fuel-primary pressure.
(C) Change components, check sensor and if
necessary replace it, check fuel system
and if necessary repair it.
Table 3-11. Engine Fault Codes (Deutz Engine)
SPN
FMI
Deutz
Code
Blink
Code
Error Description
Possible Reasons For Error
Take Action For Repair (TAFR)
Go
to
Discount-Equipment.com
to
order
your
parts