SECTION 6 - JLG CONTROL SYSTEM
6-38
31215031
FUNCTION CUTOUT:
18*
1
2
3
NO: No drive cutout.
BOOM CUTOUT: Boom function cutout while driving above elevation.
DRIVE CUTOUT: Drive & steer cutout above elevation.
1
* Certain market selections will limit function cutout options or alter default setting.
GROUND ALARM:
19
1
2
3
4
NO: No ground alarm installed.
DRIVE: Travel alarm sounds when the drive function is active (Option).
DESCENT: Descent alarm sounds when lift down is active (Option).
MOTION: Motion alarm sounds when any function is active (Option).
4
DRIVE:
20
1
2
3
4WD: Four wheel drive.
2DW: 2 wheel drive
2WD W/ 2-SPEED: Two wheel drive with 2-speed valve.
1
DISPLAY UNITS:
21*
1
2
IMPERIAL: DEG F, PSI, LBS .
METRIC: DEG C, KPA, KGS
1
* Certain market selections will alter default setting.
LEVELING MODE:
22*
1
2
ALL FUNCTIONS: Platform level with all functions.
LEVEL LIFT/TELESCOPE: Platform level on lift and telescope only.
1
* Only visible under certain model selections.
DRIVE PUMP:
23*
1
2
3
4
SAUER DANFOSS: Machine equipped with Sauer Danfoss drive pump.
EATON: Machine equipped with Eaton drive pump.
M46-XXXX: Machine equipped with M46-XXXX drive pump.
830XXXXX: Machine equipped with 830XXXXX: drive pump
1
* Only visible under certain model selections.
CLEARSKY:
24
1
2
NO: ClearSky (telematics) options is disabled.
YES: ClearSky (telematics) option is enabled.
1
Table 6-4. Machine Configuration Programming Information (Software Version P6.30)
Configuration
Label/Digit
Number
Description
Default
Number
Go