Section 1.  General Information

1.1 Introduction

This manual contains information for the proper 

installation and operation of the Hi-E

2

  and Hi-E

2

R Model 

EHE pool/spa heater. Certain sections are specific to 

United States or Canadian installations, and are labeled 

United States or Canada. Procedures in this manual must 

be followed exactly. To obtain a copy of this manual 

contact Zodiac Pool Systems, Inc. ("Zodiac

®

"). For 

address information. See back cover.

1.2 Description

The Hi-E

2

 Low NOx heater is a very efficient gas-fired 

pool and spa heater. Its combustion system includes a 

heat exchanger which extracts 95% of the energy in the 

gas fuel. It has no standing pilot burner. It exceeds the 

requirements of energy conservation regulations such as 

those in California, Hawaii, New York, Oregon and other 

states which require that a pool heater have intermittent 

ignition.
The heater is designed to operate in conventional 

swimming pool and spa equipment arrangements. It 

requires 115V 60 Hz electrical power. It has the versatile 

dual-thermostat control system for pool/spa combinations.
The Hi-E

2

 is certified by CSA International to comply with 

latest editions of applicable standards. In the United States, 

the applicable standard is ANSI Standard Z21.56 for gas-

fired pool heaters. In Canada, it is Standard CSA 4.7. 

The Hi-E

2

 Low NOx heater has been designed specifically 

to heat fresh water swimming pools and spas, and with 

proper installation and care, it will provide years of 

reliable service. Do not use it to maintain pool or spa 

water temperature below 70°F. Do not use it as a heating 

boiler or general service water heater or to heat true salt 

water systems where salinity is in the 35,000 ppm range. 

For special applications, consult your Jandy Pro Series 

dealer.

1.3 Warranty

The Hi-E

2

 is sold with a limited factory warranty. A copy 

of the warranty is included in a plastic bag inside the 

heater. The warranty does not cover damage caused by 

improper installation, operation, or field modification; or 

damage to the heat exchanger caused by corrosive water. 

See Section 3.4 for guidelines on pool water chemistry.

 WARNING

Improper installation or maintenance can cause nausea 

or asphyxiation from carbon monoxide in flue gases 

which could result in severe injury, or death. For indoor 

installations, as an additional measure of safety, Zodiac 

Pool Systems, Inc. strongly recommends installation of 

suitable Carbon Monoxide detectors in the vicinity of this 

appliance and in any adjacent occupied spaces. 

Section 2.  Installation Instructions

2.1  General Requirements

All gas-fired products require correct installation to assure 

safe and satisfactory operation. The requirements for pool 

heaters include the following:

1. 

Appropriate site location and clearances.

2. 

Sufficient supply of clean air for combustion and 

ventilation.

3. 

Proper venting of products of combustion.

4. 

Properly sized gas pipe.

5. 

Properly sized gas meter.

6. 

Adequate water flow.

7. 

Provision for disposal of combustion condensate 

water.

In the United States, installation must be in accordance 

with local codes and the most recent edition of the 

National Fuel Gas Code, ANSI Z223.1/NFPA-54. The 

Code can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169

www.nfpa.org

In Canada, install the heater in accordance with local 

codes and the most recent edition of the Natural Gas and 

Propane Installation Code, CAN/CSA B149.1.

Special Precautions

Liquefied petroleum (LP) gas is heavier than air. 

Therefore, a pool heater using LP gas is subject to special 

installation rules. Consult local codes and fire protection 

authorities about specific installation restrictions.
Fuel gas and its combustion products are known to cause 

cancer or harm the reproductive process. Follow these 

installation instructions and applicable codes exactly to 

avoid this.

Содержание HI-E2

Страница 1: ...ion and or operation can create carbon monoxide gas and flue gases which can cause serious injury property damage or death For indoor installations as an additional measure of safety Zodiac Pool Syste...

Страница 2: ......

Страница 3: ...tion 17 2 12 2 Start up 17 2 12 3 Condensate 17 2 12 4 Gas Pressure 18 2 12 5 Adjustment of Water Pressure Switch 18 2 12 6 Water Temperature Rise 19 Section 3 Operating Instructions 19 3 1 Start Up P...

Страница 4: ...arranty The Hi E2 is sold with a limited factory warranty A copy of the warranty is included in a plastic bag inside the heater The warranty does not cover damage caused by improper installation opera...

Страница 5: ...building codes for additional requirements CAUTION When pool equipment is located below the pool surface a leak from any component can cause large scale water loss or flooding Zodiac Pool Systems Inc...

Страница 6: ...of the heater The correct size drill bit is usually provided with the concrete screws when purchased Place a screw in each of the holes and fasten the heater to the equipment pad see Figure 2 Do not o...

Страница 7: ...and Ventilation Air Model Required net free area in square inches sq cm for each of 2 openings one 1 near ceiling and one 1 near floor Directly Through an Exterior Wall Through Horizontal Ducts 350 88...

Страница 8: ...boratory NRTL as being compliant with the applicable requirements of the Underwriters Laboratories UL standard for safety for Venting Systems for Gas Burning Appliances Categories II III and IV ANSI U...

Страница 9: ...on inlets etc In the United States this distance must be at least 4 feet 1 21 m In Canada it must be at least 10 feet 3 04 m five 5 elbows Per Table 3 Only 16 feet of 4 vent pipe would be allowable wh...

Страница 10: ...e it can be disposed of properly Support vent piping with suitable hangers so its weight does not bear on the heater or building penetration and so that piping joints are not strained Support horizont...

Страница 11: ...wer A package of limestone gravel neutralizer is provided with the condensate assembly Remove the neutralizer from the packing and spread evenly throughout the tray and around the properly placed tube...

Страница 12: ...s control during testing When the heater is started check the supply pressure to verify that it is adequate during heater operation Undersize piping a restrictive fitting or an undersize gas meter can...

Страница 13: ...aune Vert Mauve GY Gray Gris COMB FAN Ventilateur combustion 115V 60Hz H0205500F IGN120 IND W W BK GY R BR TR TH DIGITAL IGNITION CONTROL BK Hi E2 Figure 15 Wiring diagram Hi E2 pool heater The Hi E2...

Страница 14: ...ff from a remote location Contact your local Jandy Pro Series distributor for information on the AquaLink RS control system to fit your back yard recreational needs An interrupt on off type remote can...

Страница 15: ...the brass fitting 5 Remove the temperature control sensor by removing the retainer bracket and its cap screws 6 Disconnect the limit switch wires from the limit switches The limit switches and the sho...

Страница 16: ...d A pressure relief valve is not supplied with the Hi E2 All equipment installations need to be in accordance with the manufacturers instructions To install a pressure relief valve 1 Remove the 3 4 br...

Страница 17: ...in the system when installing a PRV Any pressure relief valve installed must comply with provisions of the standard described in ANSI Z21 22 for the United Sates or CSA 4 4 in Canada Some local codes...

Страница 18: ...its operation and settings as outlined in the maintenance section of this manual 2 12 4 1 Step down Gas Pressure Regulator The step down regulator does not change requirements for gas supply piping o...

Страница 19: ...tem or a larger pump Before proceeding with either remedy verify proper heater operation Low gas input results in low temperature rise and vice versa A problem with the heater internal bypass assembly...

Страница 20: ...de of the service door and also on the inside of the control compartment door Lighting instructions are as follows 1 Turn off all electrical power to the heater at the main junction box 2 Open the con...

Страница 21: ...factor of the pool water between 7 4 and 7 6 See Table 7 for guidelines on other chemical measurements 3 4 2 Spas The proper chemical balance in spa water is more critical than in a swimming pool hea...

Страница 22: ...se spas or hot tubs 3 4 2 2 Saturation Index PH Total Alkalinity TA temperature Calcium Hardness and Total Dissolved Solids TDS play a role in whether the water is either corrosive or scale forming Th...

Страница 23: ...the 78 F 26 C level before expected usage keeping in mind to allow enough lead time for the water to reach the desired temperature 6 During the winter shut down the heater by following the lighting a...

Страница 24: ...technician when inspecting and servicing the heater To reactivate the heater in the spring have a qualified professional technician reassemble the heater as follows 1 Attach the pressure switch fitti...

Страница 25: ...lter and strainers aren t clogged that there are no mis positioned water valves that the gas or electric power supplies aren t shut off and that time clocks are properly adjusted Also be sure that the...

Страница 26: ...ixture monitors the flame and controls the combustion blower and gas valve When the temperature control requires heat the ignition control starts the blower providing a pre purge of the combustion cha...

Страница 27: ...tings or similar devices may be the problem Voltage outside of the above range may be due to poor wiring poor connections other loads such as air conditioning compressors or to an electric utility com...

Страница 28: ...ectrical power or setting the control to Off 4 5 2 3 Fireman Switch and External Interlocks Probe for voltage at point 3 the other connection of the terminal block which has a white wire connected to...

Страница 29: ...l for heat Observe that the normal sequence takes place by noting blower operation the glow of the igniter through the combustion chamber sight glass and then voltage at point 8 If the blower does not...

Страница 30: ...on heater The manometer will read zero until the gas valve opens and then it will indicate the gas orifice differential The gas orifice differential should be 4 0 0 3 WC for a unit at sea level See s...

Страница 31: ...other elevations Note that when the heater is operated with the gas valve off it will eventually lock out because the ignition control does not sense flame Normally there will be enough time to obtai...

Страница 32: ...ockage in the combustion air supply system Correct any such problems and verify normal operation by returning to the venturi system checkout procedures Pressure readings will be less if the heater is...

Страница 33: ...eration Check for blockage by disconnecting drainage tubes at the collector and the vent diffuser Probe these openings with a tool or wire hook to dislodge any debris Limestone gravel neutralizer is r...

Страница 34: ...04300 18 By Pass Valve Assembly 350 R0304400 19 Flow Control Cap 350 S0076700 20 By Pass Valve Gasket 350 R0011400 21 By Pass Valve Spring 350 R0304500 22 By Pass Valve Rod 350 R0304900 23 By Pass Val...

Страница 35: ...oor Exhaust Grill 350 R0348400 57 Indoor Vent Collar not shown 350 R0307900 58 Condensate Trap Assembly 350 R0303300 59 Limestone Gravel 350 R0306200 60 Condensate Trap Cover 350 R0213300 Venturi Hard...

Страница 36: ...ired Heater Installation Operation Manual 42 46 65 66 12 45 44 43 55 56 86 40 30 38 41 83 84 30A 34 32 33 39 36 37 35 6 4 10 1316 48 85 54 1 75 81 87 53 50 51 52 17 14 3 18 23 15 29 49 8 9 2 5 58 60 6...

Страница 37: ...Page 37 ENGLISH Jandy Pro Series Hi E2 and Hi E2R Gas Fired Heater Installation Operation Manual NOTES...

Страница 38: ...Page 38 ENGLISH Jandy Pro Series Hi E2 and Hi E2R Gas Fired Heater Installation Operation Manual NOTES...

Страница 39: ...Page 39 ENGLISH Jandy Pro Series Hi E2 and Hi E2R Gas Fired Heater Installation Operation Manual NOTES...

Страница 40: ...CA 92081 1 800 822 7933 www jandy com ZODIAC is a registered trademark of Zodiac International S A S U used under license All other trademarks referenced herein are the property of their respective ow...

Отзывы: