JANDS – Event 4 Version 5 Users Manual
Page 10
Revision 5.0.0.5
25/11/02
1 Hardware
Setup
1.1 Connecting
Power
Plug the socket end of the power cord into the IEC power receptacle located on the
rear face of the Event. The other end of the power cord should be plugged into a 3-pin
earthed outlet. It is important that the Event 4 is electrically grounded; if in doubt,
contact a licensed electrician.
1.2
Connecting the Output to DMX Devices
Event 4 provides two DMX outputs for connection to fixtures and dimmer systems.
The DMX output is standard on all consoles.
Connect from the console's DMX output to the DMX input on the fixtures and dimmer
racks. Check the device’s instruction manual for details on selecting DMX channels
and looping the DMX line to other devices.
1.3 Connecting
Desklights
Desklights are available as an optional accessory. Only 12V Littlite or compatible
desklights with 3-pin XLR type connectors should be used (for wiring see Appendix
A).
1.4
Connecting a Monitor
Connect any VGA monitor to the 15 pin D-connector on the back panel.
1.5
Connecting a Keyboard
Connect any keyboard, with a 5 pin Din connector, to the connector on the back panel.
1.6
Connecting a MIDI Device
The Event 4 console is equipped with a MIDI input. Use a standard MIDI cable to
connect from the MIDI device to the MIDI In connector on the backpanel (for wiring
see Appendix A). The THRU connector can be used to transmit the MIDI signal to
other MIDI equipment.
1.7
Connecting a Slave Console
Any Jands Stage 12, ESP II, EVENT or Event 4 console can be slaved to the Event 4.
Connect from the MIDI output of the slave console to the MIDI input of the main
console. This cable should be wired as detailed (for wiring see Appendix A).
1.8
Turning the Power On
Once all connections have been made the console can be turned on using the mains
power switch located on the back panel next to the power lead input.
Содержание Event 4