Page 65
1998-2006 Edition
SYMPTOM #6
PROBABLE CAUSE
SOLUTION
The main power switch is ON and all
lights are working properly. However,
when the Fuel Feed Control knob is
turned up or down, there is no variation
in convection blower speed or fuel
feed rate.
1. Stove is still running in
the 12 minute Startup
Cycle and has not
warmed up sufficiently
yet.
1. There will be no variation in convection
blower speed until the stove warms up and
there will be no variation in fuel feed rate
until stove has warmed up and the 12
minute cycle is complete. Wait until the
12 minute cycle is completed.
SYMPTOM #7
PROBABLE CAUSE
SOLUTION
Fuel feed rate and the Convection fan
speed are irregular or fluctuate.
1. Stove is connected to
electrical power using an
extension cord that is
too long.
2. Voltage supply to the
house is fluctuating or is
too low.
3. Main Control Board
processor chip is faulty.
1. Do not use extension cords to supply
power to the stove. An extension cord that
is too long or one that is made of wire of
low gauge will reduce the voltage supplied
to the stove. Contact an electrician to
install a proper power supply line to the
stove.
2. Contact an electrician or the local power
company. Check voltage fluctuation.
Adjust so that voltage is at least 110VAC.
3. If problem still exists after checking steps 1
through 3, Main Control Board is faulty.
Replace.
SYMPTOM #8
PROBABLE CAUSE
SOLUTION
On/Off switch is OFF but Exhaust
1. Stove is still hot.
1. Allow stove to cool for about 1-1/2 hours.
blower and Convection fan continue to
Exhaust blower and convection fan are
run.
designed to stay on until stove cools down
completely.
2. Low Temperature
Sensor(130F/54ºC sensor) is
faulty (stuck in the ON
position).
2. If stove has been cold for several hours,
check for continuity across Low
Temperature Sensor (130F/54ºC sensor)
terminals. If continuous, replace 130F (54ºC)
sensor.
3. Improper wiring of
several internal
components.
3. If stove was "worked on" recently, several
components within could have been wired
improperly. Contact Dealer. Check wiring
thoroughly according to this manual and
correct any problems.
SYMPTOM #9
Stove burns normally then, suddenly,
fuel stops feeding to firepot and fire
goes out but all the indicator lights
continue to work normally.
1. High limit sensor has
overheated and turned
the fuel feed off.
2.
Auger has jammed.
1. Check to see if the Green Light is ON. If
it is OFF, toggle the On/Off switch to Off
then On. Press the Reset Button. If the
green light does not illuminate, it is
confirmed that the high limit switch has
tripped. Check fuel feed rate on High and
on Low. If it conforms to this manual,
increase the Convection Blower LOW
SPEED setting. Refer to Control Board
adjustments section of this manual.
2. Empty fuel hopper of pellets and check
auger for foreign objects. Remove foreign
object from auger.
PROBABLE CAUSE
SOLUTION
Содержание J1000B
Страница 2: ......
Страница 8: ...Page vi 1998 2006 Edition ...
Страница 16: ...Page 8 1998 2006 Edition ...
Страница 20: ...Page 12 1998 2006 Edition ...
Страница 36: ...Page 28 1998 2006 Edition ...
Страница 38: ...Inside the Room and Recessed in an Interior Chase Page 30 1998 2006 Edition Recessed in an Exterior Chase ...
Страница 39: ...Corner Installation Page 31 1998 2006 Edition Installation requires standoffs to maintain clearances ...
Страница 44: ...Page 36 1998 2006 Edition ...
Страница 45: ...Page 37 1998 2006 Edition ...
Страница 46: ...VIII 5 Jamestown Control Panel Page 38 1998 2006 Edition ...
Страница 61: ...Page 53 1998 2006 Edition ...
Страница 62: ...Page 54 1998 2006 Edition ...
Страница 63: ...Page 55 1998 2006 Edition ...
Страница 64: ...Page 56 1998 2006 Edition ...
Страница 69: ...Page 61 1998 2006 Edition ...
Страница 70: ...Page 62 1998 2006 Edition ...
Страница 79: ...Appendix A 3 1998 2006 Edition ...
Страница 80: ...Appendix A 4 1998 2006 Edition ...
Страница 81: ...Appendix A 5 1998 2006 Edition ...
Страница 82: ...Appendix A 6 1998 2006 Edition ...
Страница 84: ...Appendix B 2 1998 2006 Edition ...
Страница 86: ...APPENDIX D EXHAUST BLOWER ASSEMBLY MODEL J1000 Appendix D 1 1998 2006 Edition Complete Assembly is Part 07DAA ...
Страница 87: ...APPENDIX E AUGER MOTOR BRACKET INSTALLATION Appendix E 1 1998 2006 Edition ...
Страница 90: ...Appendix F 3 1998 2006 Edition ...
Страница 93: ...APPENDIX H J1000 CROSSFLOW FAN Part 07EEG Appendix H 1 1998 2006 Edition ...
Страница 94: ...APPENDIX I 1 EXHAUST BLOWER ASSEMBLY MODEL J1000 Appendix I 1 1998 2006 Edition ...
Страница 96: ...SERVICE RECORD DATE SERVICED BY DESCRIPTION ...