13. Slide the Stove into its final position while guiding the installed vent system through the wall thimble. Refer to
Chapters III and IV (Clearances to Combustible Materials Requirements) to ensure that the final position of the stove
adheres to all the listed clearance requirements.
14. Check for wall thimble fit around the 4-3/4" (121mm) pipe, adjust as necessary and secure the wall thimble pieces
to the wall using eight screws designed for your wall material type.
15. Fill any gaps between the wall thimble and the 4-3/4" (121mm) pipe with RTV silicone.
16. Slide the 4-3/4" (121mm) End Cap/Rodent Screen (part# 11) so that the sleeve fits inside the end of the 4-3/4"
(121mm) pipe extension and the 3" (76mm) exhaust pipe slides through the 3" (76mm) hole at the center of the End
Cap. Secure the cap in place using one #8 x 1/2" Teck Screw through the side of the 4-3/4" (121mm) pipe.
17. Slide the 3" (76mm) Double Wall Rain Cap (part # 9) over the end of the 3" (76mm) exhaust pipe with the open
end of the cap facing downward at an angle, as shown in Figure B. Secure the Rain Cap to the 3" (76mm) exhaust
tube using three #8 x 1/2" Teck Screws. Space the screws evenly around the 3" (76mm) tube.
Installation of the Coaxial Through-The-Wall 45 Degree Vent System is now complete. Check the entire exhaust
system to ensure that there are no exhaust gas leaks.
Содержание J1000B
Страница 2: ......
Страница 8: ...Page vi 1998 2006 Edition ...
Страница 16: ...Page 8 1998 2006 Edition ...
Страница 20: ...Page 12 1998 2006 Edition ...
Страница 36: ...Page 28 1998 2006 Edition ...
Страница 38: ...Inside the Room and Recessed in an Interior Chase Page 30 1998 2006 Edition Recessed in an Exterior Chase ...
Страница 39: ...Corner Installation Page 31 1998 2006 Edition Installation requires standoffs to maintain clearances ...
Страница 44: ...Page 36 1998 2006 Edition ...
Страница 45: ...Page 37 1998 2006 Edition ...
Страница 46: ...VIII 5 Jamestown Control Panel Page 38 1998 2006 Edition ...
Страница 61: ...Page 53 1998 2006 Edition ...
Страница 62: ...Page 54 1998 2006 Edition ...
Страница 63: ...Page 55 1998 2006 Edition ...
Страница 64: ...Page 56 1998 2006 Edition ...
Страница 69: ...Page 61 1998 2006 Edition ...
Страница 70: ...Page 62 1998 2006 Edition ...
Страница 79: ...Appendix A 3 1998 2006 Edition ...
Страница 80: ...Appendix A 4 1998 2006 Edition ...
Страница 81: ...Appendix A 5 1998 2006 Edition ...
Страница 82: ...Appendix A 6 1998 2006 Edition ...
Страница 84: ...Appendix B 2 1998 2006 Edition ...
Страница 86: ...APPENDIX D EXHAUST BLOWER ASSEMBLY MODEL J1000 Appendix D 1 1998 2006 Edition Complete Assembly is Part 07DAA ...
Страница 87: ...APPENDIX E AUGER MOTOR BRACKET INSTALLATION Appendix E 1 1998 2006 Edition ...
Страница 90: ...Appendix F 3 1998 2006 Edition ...
Страница 93: ...APPENDIX H J1000 CROSSFLOW FAN Part 07EEG Appendix H 1 1998 2006 Edition ...
Страница 94: ...APPENDIX I 1 EXHAUST BLOWER ASSEMBLY MODEL J1000 Appendix I 1 1998 2006 Edition ...
Страница 96: ...SERVICE RECORD DATE SERVICED BY DESCRIPTION ...