Page 44
1998-2006 Edition
flame up within these 5 minutes. If a flame is present before the end of the 5 minutes, let the stove continue running
without changing any of the controls. If a flame is not present at the end of the 5 minutes, turn the wall thermostat
to the OFF position. Empty the pellets from the firepot into a non-combustible metal container and check the firepot
for proper placement and alignment with the automatic ignition device enclosure tube. Reposition and realign
firepot. Repeat Steps 9 and 10.
Warning
A few glowing embers may be present in the firepot. Never empty the contents of the firepot into the fuel hopper
or any other combustible container.
12. If the stove warms up sufficiently during the 12 minute
startup cycle, the convection blower should increase in speed.
Similarly, at the end of the 12 minute startup cycle, the FUEL ON
indicator light should begin to stay ON for longer periods and
stay OFF for shorter periods. An increased amount of fuel
should begin to feed into the firepot.
13. If the stove is set to run in the Automatic Mode, let the stove
burn at this rate for 5 minutes. After 5 minutes, adjust the Feed
Rate Control Knob to the desired position, wait 2 minutes then
adjust the Draft Control Knob accordingly for an efficient burn.
During the first hour of burn, check for proper air to fuel ratio and
efficient flame characteristics and adjust the Draft Control Knob
NOTE
If the stove does not warm up sufficiently by
the end of the 12 minute startup cycle, the
FUEL ON indicator light will turn OFF and
the green POWER ON indicator light will
flash once every two seconds indicating that
the stove did not warm up sufficiently. If this
occurs, turn the main power switch to OFF
then back to ON and turn the wall
thermostat to the ON position. This will
reinitiate the 12 minute startup cycle.
if necessary. If you plan to leave the Fuel Feed Control Knob at one fixed position for all future burn sessions, it is
not necessary to adjust the Draft Control Knob again. However, check for efficient flame characteristics at least
once a day.
NOTE
When set in the Semiautomatic Mode, the
12 minute startup cycle can only be
restarted by turning the main power switch
to OFF then to ON. If the electrical power is
interrupted for any reason, the startup cycle
will be initiated when the power is restored
and the wall thermostat is turned to the ON
position.
14. If the stove is set to run in Semiautomatic Mode, turn the
Fuel Feed Control Knob to a number no greater than 4-1/2, wait
2 minutes then adjust the Draft Control Knob accordingly for an
efficient burn. Let the stove burn at this rate for 10 minutes. At
the end of the 10 minutes, turn the wall thermostat to the OFF
position. The fuel feed rate will be lowered to the default LOW
rate. Let the stove burn at this rate for 10 minutes. At the end
of the 10 minutes, check for efficient flame characteristics, flame
height and number of embers in the firepot. If the flame height
is less than 2 inches and if there are less than about 10 pieces
of embers in the firepot, reduce the Draft Knob setting number
by 1/2. For example:If the Draft Knob was at #3, reduce it to #2-1/2. Check again after 10 minutes. If the flame
height has increased and if the number of embers in the firepot is greater, then turn the wall thermostat to ON. The
fuel feed rate will increase to the rate determined by the position of the Fuel Feed Control Knob. Let the stove burn
at this rate for 10 minutes. Check for efficient flame characteristic. If efficient flame characteristic is not observed,
reduce the Fuel Feed Control Knob setting number by 1/2. Check again after 10 minutes. If necessary reduce the
Fuel Feed Control Knob setting, incrementally, until an efficient flame characteristic is observed.
If you encounter any difficulties achieving a flame within the first 5 minutes or establishing an efficient flame pattern,
please consult the Trouble Shooting Guide in this manual. If you are unable to remedy the problem, please contact
your local Jamestown Dealer.
Содержание J1000B
Страница 2: ......
Страница 8: ...Page vi 1998 2006 Edition ...
Страница 16: ...Page 8 1998 2006 Edition ...
Страница 20: ...Page 12 1998 2006 Edition ...
Страница 36: ...Page 28 1998 2006 Edition ...
Страница 38: ...Inside the Room and Recessed in an Interior Chase Page 30 1998 2006 Edition Recessed in an Exterior Chase ...
Страница 39: ...Corner Installation Page 31 1998 2006 Edition Installation requires standoffs to maintain clearances ...
Страница 44: ...Page 36 1998 2006 Edition ...
Страница 45: ...Page 37 1998 2006 Edition ...
Страница 46: ...VIII 5 Jamestown Control Panel Page 38 1998 2006 Edition ...
Страница 61: ...Page 53 1998 2006 Edition ...
Страница 62: ...Page 54 1998 2006 Edition ...
Страница 63: ...Page 55 1998 2006 Edition ...
Страница 64: ...Page 56 1998 2006 Edition ...
Страница 69: ...Page 61 1998 2006 Edition ...
Страница 70: ...Page 62 1998 2006 Edition ...
Страница 79: ...Appendix A 3 1998 2006 Edition ...
Страница 80: ...Appendix A 4 1998 2006 Edition ...
Страница 81: ...Appendix A 5 1998 2006 Edition ...
Страница 82: ...Appendix A 6 1998 2006 Edition ...
Страница 84: ...Appendix B 2 1998 2006 Edition ...
Страница 86: ...APPENDIX D EXHAUST BLOWER ASSEMBLY MODEL J1000 Appendix D 1 1998 2006 Edition Complete Assembly is Part 07DAA ...
Страница 87: ...APPENDIX E AUGER MOTOR BRACKET INSTALLATION Appendix E 1 1998 2006 Edition ...
Страница 90: ...Appendix F 3 1998 2006 Edition ...
Страница 93: ...APPENDIX H J1000 CROSSFLOW FAN Part 07EEG Appendix H 1 1998 2006 Edition ...
Страница 94: ...APPENDIX I 1 EXHAUST BLOWER ASSEMBLY MODEL J1000 Appendix I 1 1998 2006 Edition ...
Страница 96: ...SERVICE RECORD DATE SERVICED BY DESCRIPTION ...