4-124
4222983 Second Edition
ELECTRICAL
4
Raise/Lower Circuit
Perform a factory reset and actuator calibration
before replacing RCU.
Cutting units will not raise.
Cutting units will not lower.
Left cutting unit will not raise and lower.
Center cutting unit will not raise and lower.
Probable Cause
Remedy
Faulty raise switch.
Test raise switch using LCD display “Switch Test”. (See “Switch Test” on page 4-85.)
If the raise switch does not activate during the LCD “Switch Test”, bench test the switch.
(See “Raise/Lower Switch Assembly Test” on page 4-131.)
Faulty connections.
Check connections; make sure connections are clean and tight.
Faulty wiring harness.
Make sure wiring harness is free of nicks and cuts and not pinched to machine frame.
Probable Cause
Remedy
Faulty lower switch.
Test lower switch using LCD display “Switch Test”. (See “Switch Test” on page 4-85.)
If the lower switch does not activate during the LCD “Switch Test”, bench test the switch.
(See “Raise/Lower Switch Assembly Test” on page 4-131.)
Faulty connections.
Check connections; make sure connections are clean and tight.
Faulty wiring harness.
Make sure wiring harness is free of nicks and cuts and not pinched to machine frame.
Probable Cause
Remedy
Actuator Not Calibrated
Complete maintenance mode calibration or factory reset. Verify fault is eliminated.
Faulty connections.
Check connections; make sure connections are clean and tight.
Faulty wiring harness.
Make sure wiring harness is free of nicks and cuts and not pinched to machine frame.
Faulty left reel enable switch
Test left reel enable switch using LCD display “Switch Test”. (See “Switch Test” on
page 4-85.)
If the left reel enable switch does not activate during the LCD “Switch Test”, bench test the
switch. (See “Rocker Switches Test” on page 4-130.)
Probable Cause
Remedy
Actuator Not Calibrated
Complete maintenance mode calibration or factory reset. Verify fault is eliminated.
Faulty connections.
Check connections; make sure connections are clean and tight.
Faulty wiring harness.
Make sure wiring harness is free of nicks and cuts and not pinched to machine frame.
Faulty center reel enable switch
Test center reel enable switch using LCD display “Switch Test”. (See “Switch Test” on
page 4-85.)
If the center reel enable switch does not activate during the LCD “Switch Test”, bench test
the switch. (See “Rocker Switches Test” on page 4-130.)
Содержание Eclipse 322
Страница 1: ...Eclipse 322 Riding Greens Mower Technical Repair Manual 62801 62803 62805 Second Edition...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 12: ...1 4 4222983 Second Edition SAFETY 1 4181861 4181860 4181862 5 2 4 3 1 105dB LWA 6 4216820 Rev A 7...
Страница 13: ...SAFETY 4222983 Second Edition 1 5 1 9 41 8 1 8 64 8 4127335 10 4181865 11...
Страница 20: ...1 12 4222983 Second Edition SAFETY 1 Page Intentionally Blank...
Страница 110: ...4 36 4222983 Second Edition ELECTRICAL 4 Page Intentionally Blank...
Страница 128: ...4 54 4222983 Second Edition ELECTRICAL 4 Page Intentionally Blank...
Страница 241: ...ELECTRICAL 4222983 Second Edition 4 167 4 Page Intentionally Blank...
Страница 242: ...4 168 4222983 Second Edition ELECTRICAL 4...
Страница 266: ...5 24 4222983 Second Edition CHASSIS 5 Page Intentionally Blank...
Страница 332: ...IX 14 4222983 First Edition INDEX IX...
Страница 333: ......
Страница 335: ......
Страница 336: ......