JA-14K(R) Security System Control Panel
64 / 72
MNX22101
11.4 RF Signal
Window for graphic representation of radio band interference intensity with the possibility to select from the used
radio modules. Presence of unknown signals in the band is indicated in red. Green colour identifies
communication signals of the system (enrolled devices) and blue is used to display the selected device from the
list of the
Highlighted device
item (see figure). Grey colour indicates a background (jamming). With the
Disable unknown devices
option, it is possible to filter out the unknown devices and to display only the
devices enrolled in the system.
Monitored interference logging (when the RF Signal window is open) can be exported from the main menu
to a file with the FDR suffix and the
button can be used to import it back for viewing.
11.5 Service
Switching the control panel mode between the Unset status (when changes of setting
can be done in all tabs except the Settings tab) and the Service mode (changes can be done
in the Devices tab, incl. enrolling, changes of internal settings and deletion of devices).
11.6 Refresh
Updating the internal settings of devices after a hardware change.
11.7 Online
Connection or disconnection of N-Link from the control panel using a USB cable.
After the connection the software will find the port the control panel uses for communication
automatically.
11.8 Internet
Remote connection or disconnection of N-Link from the control panel via the Internet. A precondition for
establishing the connection is the properly entered registration code (it is automatically pre-entered from
the database that was used to program the control panel), phone number of the SIM card in the control panel
(also pre-entered from the Installation Information) and the computer connected to the Internet. Remote access
can be disabled in the Communication tab / Communication Type = Without remote communication.