JA-14K(R) Security System Control Panel
51 / 72
MNX22101
System profiles
Selection from pre-set system profiles according to requirements.
Default
Parameters set by factory default with the option to
modify them according to needs
EN 50131-1, Grade 2
Some parameters are pre-set automatically to
comply with EN 50131-1, Grade 2 (low – middle
risks) with no option to be modified
Timer setting
In each section, the entry and exit delays are measured separately.
If different exit delays are defined for detectors within one section the longest
delay is measured. In case of different entry delays the one that belongs to the
activated detector is measured. If more detectors are activated, the shortest
one of the defined entry delays is measured.
Alarm duration
Alarm duration – valid for all sections. Range 5 s – 20 min.
Entrance delay
Range 5 s – 2 min.
Exit delay
Range 5 s – 2 min.
Entrance delay by garage
door
Range 5 s – 2 min.
Exit delay by garage door
Range 5 s – 2 min.
Period of waiting for alarm
confirmation
Waiting time for alarm confirmation by another detector of a set section. Valid
for all detectors with the reaction Confirmed immediate / Confirmed delayed A
(1 – 60 min.)
Waits for confirmation of
fire by another detector
Waiting time for fire alarm confirmation by another detector. Valid for all
detectors with the reaction Fire confirmed. (1 – 60 min.)
Delayed report to ARC
When enabled, an Internal alarm will be triggered after the entrance delay has
timed out, but the system waits for 15 s to send an alarm report to the ARC. A
user has 15 s more to unset the system without triggering an alarm reported to
the ARC.
Ways of setting
Selection of the way the system manages the setting process. From the lowest
level when the system can be set regardless of active devices and faults
in system to the highest level when the system cannot be set at all with active
devices (instant zone).
Set always
Set always regardless of the system status (faults,
active devices,..)
Set with warning
Optically indicates (on the functional button and
display) the system status (faults, active elements,
low battery or backup battery) for 8 seconds and
sets automatically once this period expires. Setting
is also possible by repeatedly pressing the functional
button (or by pressing the ENTER key).
Set after confirmation
Optically indicates (functional button and display)
the system status (faults, active elements, low
battery or backup battery) for 8 seconds. Can be set
ONLY by repeatedly pressing the functional button
(or by pressing the ENTER key).
Don´t set with an active
element
Optically indicates (functional button and display)
the system status (faults, active elements, low
battery or backup battery) for 8 seconds. Can be set
by repeatedly pressing the functional button (or by
pressing the ENTER key) but only if the active
detector is of the DELAYED or NEXT DELAYED
reaction type. An active element with any other
alarm reaction CANNOT be set this way.
ATTENTION!!! this also applies to remote control
(Voice menu, SMS, web or smart application, action
through calendar).