JA-14K(R) Security System Control Panel
58 / 72
MNX22101
10.11 ARC tab
This tab is used to set communication for alarm receiving centres. If in the Communication tab the access of the
service technician is restricted, this parameter can only be set by a person with the ARC Technician
authorization level. The option is also unavailable if the JABLOTRON communication is selected, which
considerably simplifies setting of the communication part of the system. To make changes in this tab you do not
need to be in the Service mode.
ARC enabled
– possibility to disable the set communication
Next ARC is the backup
- if enabled, the next position will only be used if data cannot be transmitted from
the current one.
Protocol
– transmission protocol setting
Communicator
– if the selected protocol can be transmitted to ARC in more ways, the communicator type
is selected here. The options are GSM, LAN, Phone line and Automatically, but only the currently available
options are visible. The Automatic option uses a combination of LAN/GSM communicators, which primarily uses
LAN and in a case of unavailable LAN switches to backup GSM. In case of failure of transmission from both
communicators the system reports a fault – data not transferred to ARC.
Domain 1 (tel. 1)
– setting of the main domain (using URL or IP address), or the main phone number
depending on the used protocol. If IP communication is used, you must enter the communication port after the
IP address, separated with a colon. You will obtain the communication port and IP address data from the ARC
the communication is routed to. If no communication port is filled in, the event will not be transmitted
Domain 2 (tel. 2)
– setting of a backup domain (using URL or IP address) or a backup phone number
depending on the used protocol
Section ID
– setting of the building identification (common for the whole building or individually for sections).
Warning: The default setting is zero, with which the communicator will not send any reports!
Reported events
– selecting types of reported events and the possibility of setting codes of supplementary
reports (PG outputs)