JABLOTRON
ALARMS
a.s.
Pod
Skalkou
4567/33
46601
Jablonec
n.
Nisou
Czech
Republic
www
.jablotron.com
||
|
JA-14K(R) Security System Control Panel
13 / 72
MNX22101
Parts of the JA-14K control panel (changeable parts) are:
−
MicroSD card 4GB or higher – meant as storage to save events, pictures from PIR detectors and cameras
To extend control panel options use:
−
The JA-111R radio module (from default pre-installed in the JA-14KR kit)
−
The JA-190X PSTN communicator
−
The JA-190Y GSM communicator
−
The SA-214/2.6 Ah back-up battery
−
JA-114HN inputs/outputs
Control panel accessories include:
−
1pc Extension USB cable (20 cm) installed in the control panel
−
1pc Fuse T 0.2 A; 250 V (meant to protect a 230 V circuit)
−
1pc Fuse T 0.4 A; 250 V (meant to protect a 110 V circuit)
−
3pcs Fasteners 8 mm
−
3pcs Screws 40 mm
−
3pcs Ties 100 mm
−
EN product sheet (short version)
3.2 Indication LEDs on the control panel board
The following indication LEDs are on the main board:
Description
Colour Meaning
COMM
green
Flashing during operation of the communication BUS indicates correct functioning
FAULT
yellow Permanently lit indicates a general error in the system (more information provided
by N-Link or a keypad with a display)
GSM
red
Status indication of a supplementary communicator (GSM or PSTN)
USB
yellow Indicating USB connection to a PC
3.3 Additional connectors on the control panel PCB
The control panel has a RESET jumper on its PCB, thanks to which the system can be set to factory default
settings (if enabled by the parameter “Reset enabled”). The procedure is very precisely described in chapter 12
Reset of the control panel.
There is a 10 pin connector on all versions of control panels meant to be used for connecting a supplementary
communicator. Also an RJ connector (RJ-44) is placed on the control panel PCB and serves for the connection of
the JA-111R radio module if installed inside the control panel box. It is strictly forbidden to connect any device to
this connector out of the control panel box. There is also a LAN connector for connection to the Internet and one
special connector designed for a tamper contact to be connected. It indicates any attempt at damaging the front
cover or opening the control panel. A rear tamper contact is not included with this version of the control panel.
3.4 Connection terminals on the control panel PCB
The control panel of a security system has the requirement to be connected to the mains (230 V / 50 Hz or
110 V / 60 Hz) power permanently. For more detailed information see the chapter 16 Technical specifications.
The mains power is connected via terminals equipped with a replaceable fuse. The control panel is a protection
class 2 device with double isolation. That´s why a 2-wire cable is enough (just a live wire and a neutral wire).
With a 3-wire cable leave the protective earth wire disconnected and isolated.
Caution
:
Don´t ever connect the earth wire to any terminal in the control panel!
For powering the control panel with a low voltage and BUS security isolation from mains power, a small
protective isolating transformer is used. Using the small green terminal connects to the control panel.
Internal communication between the control panel and connected devices is performed via the 4-wire BUS. It is
realized for the JA-14K(R) panel by a single four-colour terminal (red, yellow, green and black).
A built-in USB connector type B is placed on control panel PCBs. Using a short extension it is possible to
establish a connection with a PC via the USB cable without opening the control panel.