TDIF
This format also uses three bi-directional cables carrying eight channels of audio each, for a total of 24
channels of digital I/O.
ADAT
Lightpipe optical fibers carry eight channels of digital audio. This format is unidirectional so you’ll need three
input and three output Lightpipe “cables” for 24 channels of ADAT
I/O.
To select a digital I/O format:
1. Make sure that all your cabling is connected properly.
2. Press
the
DIG IN
key on the
Session Controller
or use the
MENU/PREV
, arrow keys and
ENTER
key
to go to the
MAIN / DIGIO MENU / DIG IN FORMAT
menu and press the
ENTER
key.
3. Use the up and down arrow keys to select the digital format of your choice and press the
ENTER
key.
Note: If you do not have a particular card installed you will get an alert dialog stating:
NO ________ CARDS INSTALLED
.
To select tracks for digital input:
1. Press
SHIFT+DIG IN(ROUTE)
key on the
Session Controller
or use the
MENU/PREV
, arrow keys and
ENTER
key to go to the
MAIN / DIGIO MENU/ DIGITAL I/O
ROUTING
menu and press the
ENTER
key.
2. Use the up and down arrow keys to select
MULTI-CH IN TRKS
and press the
ENTER
key.
3. Use the right and left arrow keys to select
ALL
or
SELECT
and press the
ENTER
key.
To select source and destination tracks for the digital 2-channel I/O:
1. Press
SHIFT+DIG IN(ROUTE)
key on the
Session Controller
or use the
MENU/PREV,
arrow and
ENTER
keys to go to the
MAIN / DIGIO MENU/ DIGITAL I/O
ROUTING
menu and press the
ENTER
key.
2. Use the up and down arrow keys to select
2 CH I/O ROUTING
and press the
ENTER
key.
3. Use the right, left, up and down arrow keys to select
IN L, IN R, OUT L
or
OUT R
fields, enter the desired
track numbers in each one and press the
ENTER
key.
Time Code
There are two distinct protocols of positional time code that are supported by RADAR
24: SMPTE/EBU
and MIDI time code or MTC. Both support all industry standard frame counts and rates. While chasing time
code it is normal practice to reference RADAR
24’s clock either directly to the incoming time code signal or
to an external word clock or video sync source. These clock sources are set separately in the
MAIN / SYNC MENU /
SYNC REFERENCE
menu.