12
12
12
12
!
!
A.C. Power
Connect RADAR
24 to the A.C. mains using the supplied power cord. The power switch is located on the
left side of the front panel. See D
IAGRAM
1.0.
IMPORTANT NOTE:
Make sure the
VOLTAGE SELECTOR
switch on the rear panel is set
to the appropriate setting before applying power to the unit. Incorrect voltage settings are
an electrical and fire hazard and can cause irreparable damage to your unit.
SCSI
Insure that the
Active Terminator
is attached securely to the external SCSI connector on the rear of the unit.
If additional external SCSI devices are used, remove the terminator, connect the devices and place the
terminator on the last device in the chain.
IMPORTANT NOTE:
Make sure that the last device in the SCSI chain is terminated
using the supplied active terminator. Incorrect termination can cause BAD things to
happen to your audio.
Sync Reference
Sync reference is one of the keys to reliable digital audio interfacing and accurate positional synchronization.
WORDCLOCK/ VIDEO
Word clock and video sync can both be used as external clock sources for the RADAR
24. The
WORDCLOCK/
VIDEO-IN
connector accepts either a word clock or a video sync source. The current selection in
MAIN / SYNC
MENU / SYNC REF
determines which of these formats will be
used as the external sync source.
Word clock is a clock signal running at the same frequency as the sampling frequency of the digital audio
being transferred or recorded. It enables multiple digital devices to be locked together so that audio can be
reproduced, transferred and recorded without any digital noise or interference.
To slave RADAR
to external word clock:
1. Connect a word clock source to the
WORDCLOCK/ VIDEO–IN
using a 75-ohm BNC terminated cable.
2. Use
the
MENU/PREV
, arrow keys and
ENTER
key to go to the
MAIN / PROJ MENU / SAMPLE RATE
, menu and
make sure that the project sample rate matches the incoming word clock frequency.
3. Press
the
SYNC/OFFSET
key on the
Session Controller
or
KC-24
or use the
MENU/PREV
key, arrow
keys and
ENTER
key to go to the
MAIN / SYNC MENU / SYNC REFERENCE
menu and hit the
ENTER
key.
4. Use the arrow keys to select
SYNC REFERENCE: WORDCLK : 48 KHZ
and press the
ENTER
key.
Note: The word clock frequency value displayed in the Sync Reference dialog will depend on the sampling rate of the
current project NOT the rate of the incoming word clock signal.