OCEANO HD-55 Pull & Lift – User Guide
System:
HD-55
Preventive Maintenance
Sub-system
: HD-55
Reference:
PM04
Page:
2/2
Subject:
Checking and Changing the
batteries
Maintenance level: 2
Duration:
10 minutes
Part 3 - Closing the Actuator
Step
Action
1.
Clean the closing cover seals and check the condition of the screw joints and change
them if there is the slightest trace or scratch (JTR50-DF801).
2.
Grease the seals with silicon grease (e.g. RHONE POULENC or MOLIKOTE silicon
grease grade 33).
3.
Reassemble in the reverse order, not omitting to connect the acoustic head.
4.
Perform an operating test, through the remote control unit as described in section III.2.
5.
End of procedure.