OCEANO HD-55 Pull & Lift – User Guide
System:
HD-55
Preventive Maintenance
Sub-system
: HD-55
Reference:
PM01
Page:
1/1
Subject:
Cleaning the HD-55
Maintenance level:
1
Duration:
10 minutes
Fresh water, liquid soap for the transducer cap
Do not use alcohol or petrol-based solvents on the neoprene casing
None
During the retrieval operation, it may happen that the FSR heavy duty
unit be dragged on
the sea-bed, thus collecting sediments (sand, mud...). After each retrieval, systematically
apply the following procedure:
Step
Action
1.
First, thoroughly flush the whole unit with sea-water.
2.
When all foreign particles have been removed, flush the assembly with
fresh water
.
3.
Visually inspect the acoustic actuator for proper condition and in particular the acoustic
head.
4.
Wash the acoustic head with soapy water if fatty matters or deposits are present (mud),
the neoprene boot should always be free of grease prior to immersion. Do not use
alcohol or petroleum based solvents.
5.
Dismantle, clean and immediately grease the various axis (hook, lever, sheave).
6.
Reassemble and rearm the unit.
7.
Fit the safety pin in position (9102987).
8.
End of procedure.
OCEANO HD-55 Acoustic release is now ready for storage.
Equipment
Precaution
Preliminary
Steps
Procedure
MU-HD55P&L-AN-001 Ed. G – October 2013