Operation Manual – ITW GSE 6400 Tier 4
b) Electrical System (12 VDC) – Check Battery Terminals
i.
Periodically, open the battery compartment panel in the right cable tray and visually
check the battery cable connectors and battery posts. If corrosion is observed,
disconnect the cables and clean battery posts and connectors with a wire brush or
special battery post-cleaning tool. Coat the posts and connectors with a light film of
petroleum lubricant before reconnecting the cables.
c) Electrical (28.5 VDC System) -- Check Output Voltage
i.
Check the output voltage and be sure it is set for
28.5 VDC System
. Adjustment can be
made using the Setup menu. (See Chapter 1-3, paragraph 3.a.)
c) “BR” Checks and Operations (Break-In Period, Once After 50-150 hrs.)
The following procedures are precautionary measures taken on most new engines. If a problem
occurs with any of the following issues, be sure to recheck it after the next 50-150 hours.
1) Engine
a) Check for leaks and correct. This involves an overall inspection of the engine and may
require some maintenance if leaks are found. Refer to the engine manufacturer’s
operations manual for assistance.
b) Change all fuel filter elements. Metal shavings from the new fuel tank can clog the filter.
c) Change crankcase oil. New engines often release metal shavings more frequently.
Therefore, the crankcase oil must be changed as a precautionary measure.
d) Change oil filter element. The oil filter should be changed with the oil.
e) Check engine and generator mounts to ensure they are properly installed and they have not
worked loose. (Torque is set at 100 N-m, 73.7 ft-lb.).
f) Check coolant additive concentration. Refer to the engine manufacturer’s operations
manual for assistance.
g) Steam clean the engine to free it of oil and dirt to prevent uneven engine cooling “hot
spots”. The oil and dirt can also fall into the engine and fuel system when covers are
removed during repair work.
h) Inspect the water pump weep hole for indication of a steady leak. If a steady flow of coolant
or oil is observed, replace the water pump with a new or rebuilt unit. Refer to the engine
manufacturer’s operations manual for assistance.
OM2248 Rev B
Page 56 of 104
Содержание 6400 Tier 4
Страница 49: ...Operation Manual ITW GSE 6400 Tier 4 c Black Box OM2248 Rev B Page 48 of 104 ...
Страница 53: ...Operation Manual ITW GSE 6400 Tier 4 OM2248 Rev B Page 52 of 104 ...
Страница 96: ...Operation Manual ITW GSE 6400 Tier 4 This page is intentionally left blank OM2248 Rev B Page 95 of 104 ...
Страница 104: ...OM2248 Rev B Page 103 of 104 ...