Operation Manual – ITW GSE 6400 Tier 4
9) Replacing the Control Board Battery
Before removing the Control Board and to avoid any static discharge to the Control Board during
the replacement of the battery, please take ESD (Electro Static Discharge) precautions
.
*
Important Note!
Before you remove the battery from the holder, make sure that the replacement battery is within reach, as
the
Control Board must not be without battery power for more than 30 seconds
.
Otherwise, all software and the setup data will be erased. *
Fig. 8.2.3 Control Board (front view)
To replace the battery,
Switch OFF
the unit
by means of Q1. Remove the Control Board from its 4 posts
marked with
a in Figure 8.2.3. Place the PCB on an insulated surface, with the back side face up.
Fig. 8.2.4 Control Board (rearview)
Blue LED (D5)
Battery holder and
battery
OM2248 Rev B