Figure 43: Impeller installation
5.
Locate and install casing gasket (400) on casing gasket feature. Use vacuum grease or other inert
assembly paste to locate gasket in sealing feature. Any compound used must be compatible with
pumped fluid.
6.
Lower casing (102V) onto back pull-out assembly and tighten casing bolts (901.11) to IOM specified
torque values.
NOTICE:
•
During Casing (102V) installation rotate shaft (210) consistently while tightening casing
bolts (901.11) to ensure no binding occurs.
•
Use casing bolts (901.11) to maintain a consistent gap between casing (102V) and cas-
ing cover (161) during assembly.
7.
Where possible, verify front clearance between casing (102V) and impeller (230) through the dis-
charge nozzle.
Table 6: Acceptable front clearances
Size
mm
160
0.38 -0.12/+0.00
200
0.38 -0.12/+0.00
250
0.38 -0.00/+.12
315
0.38 -0.00/+.12
400
0.38 -0.00/+.12
8.
If using a cartridge seal, tighten set screws in seal locking ring to secure seal to shaft and remove
centering clips, verify and follow all seal manufacturer instructions prior to startup.