Open the suction valve.
•
Open any recirculation or cooling lines.
1.
Fully close or partially open the discharge valve, depending on system conditions.
2.
Start the driver.
3.
Slowly open the discharge valve until the pump reaches the desired flow.
4.
Immediately check the pressure gauge to ensure that the pump quickly reaches the correct dis-
charge pressure.
5.
If the pump fails to reach the correct pressure, perform these steps:
a) Stop the driver.
b) Prime the pump again.
c)
Restart the driver.
6.
Monitor the pump while it is operating:
a) Check the pump for bearing temperature, excessive vibration, and noise.
b) If the pump exceeds normal levels, then shut down the pump immediately and correct the prob-
lem.
A pump can exceed normal levels for several reasons. See Troubleshooting for information about
possible solutions to this problem.
7.
Repeat steps 5 and 6 until the pump runs properly.
5.10 i-ALERT
®
2 Equipment Health Monitor
WARNING:
Explosive hazard and risk of personal injury. Heating to high temperatures could cause com-
bustion of the condition monitor. Never heat the condition monitor to temperatures in excess of
149°C | 300°F or dispose of in a fire.
For all information refer to the i-ALERT
®
2 Equipment Health Monitor Installation, Operation and Mainte-
nance manual.
http://www.ittproservices.com/aftermarket-products/monitoring/i-alert2/i-ALERT2.com
5.11 Pump operation precautions
General considerations
NOTICE:
•
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow
from the suction side. This action can result in decreased performance, unexpected heat
generation, and equipment damage.
•
Risk of equipment damage from unexpected heat generation. Do not overload the driver.
Ensure that the pump operating conditions are suitable for the driver. The driver can over-
load in these circumstances:
•
The specific gravity or viscosity of the fluid is greater than expected
•
The pumped fluid exceeds the rated flow rate.
5.10 i-ALERT®2 Equipment Health Monitor
Model ICO i-FRAME, ICOH i-FRAME Installation, Operation, and Maintenance Manual
57