Sizes
Ø
DN
Forces in N | lbf
Torques in Nm | ft-lb
Fx
Fy
Fz
ΣF
Mx
My
Mz
ΣM
80-50-250
50 1,050 |
236
950 | 214 1,150 | 259 1,820 | 409 980 | 723
700 | 516
800 | 590
1,450 |
1,069
80-50-315
50 1,050 |
236
950 | 214 1,150 | 259 1,820 | 409 980 | 723
700 | 516
800 | 590
1,450 |
1,069
100-65-160 65 1,300 |
292
1,200 |
270
1,470 | 330 2,300 | 517 1,050 | 774 770 | 568
840 | 620
1,550 |
1,143
100-65-200 65 1,300 |
292
1,200 |
270
1,470 | 330 2,300 | 517 1,050 | 774 770 | 568
840 | 620
1,550 |
1,143
100-65-250 65 1,300 |
292
1,200 |
270
1,470 | 330 2,300 | 517 1,050 | 774 770 | 568
840 | 620
1,550 |
1,143
100-65-315 65 1,300 |
292
1,200 |
270
1,470 | 330 2,300 | 517 1,050 | 774 770 | 568
840 | 620
1,550 |
1,143
125-80-160 80 1,580 |
355
1,440 |
324
1,750 | 393 2,760 | 620 1,120 | 826 800 | 590
910 | 671
1,650 |
1,217
125-80-200 80 1,580 |
355
1,440 |
324
1,750 | 393 2,760 | 620 1,120 | 826 800 | 590
910 | 671
1,650 |
1,217
125-80-250 80 1,580 |
355
1,440 |
324
1,750 | 393 2,760 | 620 1,120 | 826 800 | 590
910 | 671
1,650 |
1,217
125-80-315 80 1,580 |
355
1,440 |
324
1,750 | 393 2,760 | 620 1,120 | 826 800 | 590
910 | 671
1,650 |
1,217
125-80-400 80 1,580 |
355
1,440 |
324
1,750 | 393 2,760 | 620 1,120 | 826 800 | 590
910 | 671
1,650 |
1,217
125-100-20
0
100 2,100 |
472
1,900 |
427
2,350 | 528 3,670 | 825 1,230 | 907 880 | 649
1,020 | 752 1,820 |
1,342
125-100-25
0
100 2,100 |
472
1,900 |
427
2,350 | 528 3,670 | 825 1,230 | 907 880 | 649
1,020 | 752 1,820 |
1,342
125-100-31
5
100 2,100 |
472
1,900 |
427
2,350 | 528 3,670 | 825 1,230 | 907 880 | 649
1,020 | 752 1,820 |
1,342
125-100-40
0
100 2,100 |
472
1,900 |
427
2,350 | 528 3,670 | 825 1,230 | 907 880 | 649
1,020 | 752 1,820 |
1,342
150-125-25
0
125 2,500 |
562
2,240 |
504
2,750 | 618 4,350 | 978 1,470 |
1,084
1,050 | 774 1,330 | 981 2,140 |
1,578
150-125-31
5
125 2,500 |
562
2,240 |
504
2,750 | 618 4,350 | 978 1,470 |
1,084
1,050 | 774 1,330 | 981 2,140 |
1,578
150-125-40
0
125 2,500 |
562
2,240 |
504
2,750 | 618 4,350 | 978 1,470 |
1,084
1,050 | 774 1,330 | 981 2,140 |
1,578
200-150-25
0
150 3,150 |
708
2,850 |
641
3,500 | 787 5,500 |
1,236
1,750 |
1,291
1,230 | 907 1,450 |
1,069
2,560 |
1,888
200-150-31
5
150 3,150 |
708
2,850 |
641
3,500 | 787 5,500 |
1,236
1,750 |
1,291
1,230 | 907 1,450 |
1,069
2,560 |
1,888
200-150-40
0
150 3,150 |
708
2,850 |
641
3,500 | 787 5,500 |
1,236
1,750 |
1,291
1,230 | 907 1,450 |
1,069
2,560 |
1,888
4.6.3 Suction-piping checklist
Suction-piping checks
Check
Explanation/comment
Checked
Check that the distance between the inlet
flange of the pump and the closest elbow
is at least five pipe diameters.
This minimizes the risk of cavitation in the suction in-
let of the pump due to turbulence.
See the Example sections for illustrations.
4.6 Piping checklists
Model ICO i-FRAME, ICOH i-FRAME Installation, Operation, and Maintenance Manual
37
Содержание GOULDS PUMPS ICO i-FRAME
Страница 1: ...Installation Operation and Maintenance Manual Model ICO i FRAME ICOH i FRAME ...
Страница 2: ......
Страница 104: ...8 1 Parts list 102 Model ICO i FRAME ICOH i FRAME Installation Operation and Maintenance Manual ...
Страница 105: ...8 1 Parts list Model ICO i FRAME ICOH i FRAME Installation Operation and Maintenance Manual 103 ...