Figure 26: Back pullout removal
4.
Remove the hold-down bolts of the bearing frame foot.
5.
Remove the casing bolts.
WARNING:
•
Risk of severe physical injury or death from explosion of trapped liquid. Never use heat
to remove parts unless explicitly stated in this manual.
6.
Tighten the jackscrews evenly, using an alternating pattern, in order to remove the back pull-out as-
sembly.
You can use penetrating oil if the adapter to the casing joint is corroded.
7.
Remove the back pull-out assembly from the casing (102V).
8.
Mark and remove the shims from under the frame foot and save them for reassembly.
9.
Remove and discard the casing gasket.
You will insert a new casing gasket during reassembly.
10. Remove the jackscrews.
11. Clean all gasket surfaces.
Clean surfaces prevent the casing gasket from partially adhering to the casing due to binders and
adhesives in the gasket material.
6.6.6 Remove the coupling hub
1.
Clamp the frame adapter securely to the workbench.
2.
Remove the coupling hub.
Mark the shaft for relocation of the coupling hub during reassembly.