NOTICE:
Use only lubricants when you are sure that there can´t occur any dangerous reactions between
the pumpage and the lubricant.
NOTICE:
Make all required parts available, so that assembly can be completed quickly. The lubricants
are only effective for a short time. After that the axial movability and, thus, the automatic adjust-
ment of the elastomeres is lost.
NOTICE:
Don´t push elastomers over sharp edges. If necessary use mounting devices.
•
Put throttle bush (542.31) into quench cover (471Q) carefully.
•
Press the stationary part of the mechanical seal in the quench cover (471Q). For this you can even-
tually use a stamp with a soft surface. Unequal load can lead to cracking of the seal face.
•
Don´t damage seal face!
•
Pay attention that the stationary ring is in solid contact with the quench cover. The seal face must
be installed perpendicular to the shaft.
•
If a pin (560) is existing, be careful that it fits into the slot of the mechanical sealing, without touch-
ing the mechanical seal.
•
Insert casing cover (161) carefully, until it fits axially in the bearing frame lantern (344).
•
Push the rotating unit of the mechanical seal on the shaft (210).
•
Adjust the face on the impeller side of the mechanical seal exactly on measure A. For mechanical
seals without own set screws the fixing ring (527) serves as a stop.
NOTICE:
Push mechanical seals with bellows in such a way, that the bellow is compressed and not
stretched (danger of tearing apart!).
NOTICE:
Use anti-friction device (Molykote, etc.) between shaft sleeve and shaft only, if you are sure
that no dangerous reactions between pumped liquid and anti-friction device can occur.
•
Further assembly and installation of pump acc. Dismantling and repair of pump of Installation, Op-
eration and Maintenance Instruction.
NOTICE:
Before starting the pump connect flushing system for quench and put it into operation.
10.3 Design: S1...2 Single mech. seal, unbalanced (DIN 24960,
l
1k
/ EN 12756, design K, form U), Impeller with back vanes
You find the shaft sealing of your pump on the data sheet / the order confirmation. Refer to
Design cod-
ing system
, as well.
10.3 Design: S1...2 Single mech. seal, unbalanced (DIN 24960, l1k / EN 12756, design K, form U), Impeller with back vanes
54
ICB Installation, Operation and Maintenance Instruction