5.
After the mounting of the back pull out assembly, and its assembly into the volute casing, turn the
shaft and control the free moving of the pump in this way. The shaft sealing will cause slightly resist-
ance when turning, but there must not be any contact between metal parts.
7.1.14.2 Mount the stub shaft
1.
Insert key in the motor stump.
2.
Put anti-galling compound onto the motor stump (see Mounting,
General
).
3.
Push stub shaft up the motor shaft to measure A (see
Stub shaft mounting
image and chart).
4.
Drill countersink into motor shaft, approximately 2-3 mm depth, through the radial bore in the motor
shaft (see
Stub shaft mounting
image), by using a twist-drill with 90° tip.
5.
Remove cuttings out of the stud hole (e.g. with compressed-air), screw in and make safe thread
pins (904.41 and 904.42) (e.g. with Omnifit 100 M or Loctite).
6.
Check smooth running of stub shaft opposite to motor flange with a dial gauge. The pointer deflec-
tion of the dial gauge must not exceed 0,1 mm.
Figure 12: Stub shaft mounting
Type
Measure A by motor size
80
90
100 112 132 160 180 200
40-25-160
157 157 197 197 197 232
-
-
40-25-200
157 157 197 197 197 232
-
-
40-25-250
162 162 202 202 202 237 237 237
50-32-160
157 157 197 197 197 232
-
-
50-32-200
157 157 197 197 197 232
-
-
50-32-250
162 162 202 202 202 237 237 237
50-32-315
-
-
202 202 197 237 237 237
65-40-160
157 157 197 197 197 232
-
-
65-40-200
157 157 197 197 197 232 232
-
65-40-250
162 162 202 202 202 237 237 237
65-40-315
-
-
202 202 197 237 237 237
80-50-160
157 157 197 197 197 232 232
-
80-50-200
157 157 197 197 202 232 232 232
7.1 Maintenance
ICB Installation, Operation and Maintenance Instruction
39
Содержание Goulds Pumps ICB
Страница 1: ...Installation Operation and Maintenance Instruction ICB ...
Страница 2: ......