7.1.10 Removal of Impeller
CAUTION:
A worn impeller and/or pump housing can have very sharp edges. Wear protective gloves.
If the impeller has back vanes check the axial clearance "a" between the impeller (230) and casing cover
(161) before you continue the dismounting. Refer to sect. 8.7.1.
NOTICE:
Be sure to locate pry bars under impeller vanes to prevent damage to the impeller.
For further dismounting, and for installation, the Back Pull Out Assembly should be placed in a vertical
position. Prevent assembly from tipping!
1.
Loosen impeller nut with a sensitive hit on the wrench (right-hand thread). If necessary back up with
a pry bar in the cross boring of the stud shaft (in clamp area).
2.
Draw off the impeller (230) with two screw drivers or pry bars. Remove key (940.31).
Figure 9: Place in vertical position to prevent tipping
NOTICE:
Be sure to align the pry bars with the impeller vanes in order to prevent damage to the impeller.
3.
For further dismounting the back pullout assembly should be placed in a vertical position.
CAUTION:
Dropping, rolling or tipping units, or applying other shock loads, can cause property damage
and/or personal injury. Ensure that the unit is properly supported and secure during lifting and
handling.
7.1.11 Remove the Shaft Sealing
Before you remove casing cover refer to
Mounting Instructions for Shaft Sealing
.
1.
Unfasten hexagonal nut (902.32) (not available on all pump sizes) and take casing cover (161) out
of bearing bracket (344).