NOTICE:
Risk of equipment damage on pure or purge-oil mist-lubricated units. Remove the viewing port
plugs to verify that oil mist is flowing properly. Reinstall the plugs after confirming.
Before you start the pump, you must perform these tasks:
•
Open the suction valve.
•
Open any recirculation or cooling lines.
1.
Fully close or partially open the discharge valve, depending on system conditions.
2.
Start the driver.
3.
Slowly open the discharge valve until the pump reaches the desired flow.
4.
Immediately check the pressure gauge to ensure that the pump quickly reaches the correct dis-
charge pressure.
5.
If the pump fails to reach the correct pressure, perform these steps:
a) Stop the driver.
b) Prime the pump again.
c)
Restart the driver.
6.
Monitor the pump while it is operating:
a) Check the pump for bearing temperature, excessive vibration, and noise.
b) If the pump exceeds normal levels, then shut down the pump immediately and correct the prob-
lem.
A pump can exceed normal levels for several reasons. See Troubleshooting for information about
possible solutions to this problem.
7.
Repeat steps 5 and 6 until the pump runs properly.
5.11 Activate the i-ALERT
®
Health Monitor
WARNING:
Explosive hazard and risk of personal injury. Heating to high temperatures could cause com-
bustion of the condition monitor. Never heat the condition monitor to temperatures in excess of
149°C | 300°F or dispose of in a fire.
By using the i-ALERT
®
Health monitor or the i-ALERT
®
2 Bluetooth Equipment Health Monitor, you agree
to be bound by the Terms and Conditions of the
3.2 General description i-ALERT®2 Equipment Condi-
The health monitor is ready for activation when the pump is running and has reached a steady flow, pres-
sure, and temperature. This process only takes a few minutes.
1.
Place a small magnet on the health monitor over the ITT logo and then remove it, as this example
shows.
5.11 Activate the i-ALERT® Health Monitor
66
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
Содержание Goulds Pumps CV 3196 i-FRAME
Страница 1: ...Installation Operation and Maintenance Manual Model CV 3196 i FRAME ...
Страница 2: ......
Страница 171: ...9 1 Certificates of conformance Model CV 3196 i FRAME Installation Operation and Maintenance Manual 169 ...
Страница 174: ...9 1 Certificates of conformance 172 Model CV 3196 i FRAME Installation Operation and Maintenance Manual ...