.015
370C
371A
423B
134A
228
Figure 33: Impeller clearance setting
7.
Loosen the jack bolts (370D) several turns and tighten the locking bolts (370C) to move the impeller
away from the stuffing-box cover or seal chamber until there is 1.52 mm | 0.060 in. of clearance.
8.
Turn in the jack bolts (370D) and evenly tighten the jam nuts (423).
9.
Make sure the shaft turns freely.
5.6 Couple the pump and driver
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury or death.
Always disconnect and lock out power to the driver before performing any installation or main-
tenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all inter-
national, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for
specific instructions and recommendations.
Couplings must have proper certification to be used in an ATEX classified environment. Use the instruc-
tions from the coupling manufacturer in order to lubricate and install the coupling. Refer to driver/
coupling/gear manufacturers IOM for specific instructions and recommendations.
5.6.1 Install the coupling guard
WARNING:
•
Running a pump without safety devices exposes operators to risk of serious personal in-
jury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
5.6 Couple the pump and driver
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual