444
184
262
264
107
355
106
265
Figure 120: Backplate placement
2.
Place the repeller (262) in the backplate (444) with the sleeve side up.
3.
Place a PTFE gasket (264) on the backplate (444) and align the holes in the gasket with the holes
in the backplate.
4.
Place a stuffing-box cover (184) on the backplate (444) and align the holes in the gasket with the
holes in the backplate.
5.
Install four socket-head capscrews (265) and tighten them securely.
6.
Install a new sealing element into the gland.
7.
Install a gasket (360Q) and gland (107) on the stuffing-box cover (184).
8.
Install the nuts (355).
9.
Install a dynamic-seal assembly and nuts (370H).
370H
Figure 121: Dynamic seal installation
10. Check the stuffing-box-cover runout and rotate the indicator through 360 degrees.
An indicator reading that is greater than 0.013 mm | 0.005 in. indicates a problem.
6.6 Reassembly
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual