Voltage measured on electrode E1.
Form fields when is active the recording of data on the
input voltage (diagnostic value).
Voltage measured on electrode E2.
Form fields when is active the recording
of
data on the
input voltage (diagnostic value).
Differential voltage between the two electrodes.
FForm fields when is active the
recording
of
data on the input voltage (diagnostic value)
Common mode voltage in the electrodes.
Form fields when is active the recording
of
data
on the input voltage (diagnostic value).
Noise at low frequency measured on the electrodes.
FForm fields when is active the
recording
of
data on the input signal noise levels (diagnostic value).
Differential low frequency noise measured on the electrodes.
Form fields when is active
the
recording of data on the input signal noise levels (diagnostic values).
Low-frequency noise measured input ADC.
Form fields when is active the recording
of
data on the input signal noise levels (diagnostic values).
High frequency noise measured input ADC.
Form fields when is active the recording
of
data on the input signal noise levels (diagnostic values).
Measured equivalent resistance on the electrode 1.
Form fields when is active the
recording
of
data on the electrode resistance measurements (diagnostic values).
Measured equivalent resistance on the electrode 2.
Form fields when is active the
recording
of
data on the electrode resistance measurements (diagnostic values).
Coils excitation current.
Form fields when is active the recording
of
data related to the
sensor excitation circuit measures (diagnostic value)
Measured resistance of the excitation circuit (coil + cable).
Form fields when is active
the
recording of data relative to the sensor excitation circuit measures (diagnostic values).
Temperature measured on the sensor coils (indirect measurement).
Form fields when
the data transmission flag is active relative to the sensor excitation circuit measures (diagnostic values).
Temperature T1 (sheet sensor 1).
Form fields when the data transmission flag on board the
internal temperature measurement is active (diagnostic values).
Temperature T2 (sheet sensor 2).
Form fields when the data transmission flag on board the
internal temperature measurement is active (diagnostic values).
CPU temperature.
Form fields when the data on the card’s internal power supply voltage
measurements flag is ON (diagnostic value).
Primary power supply of CPU.
Form fields when the data on the card’s internal power
supply voltage measurements flag is ON (diagnostic value).
Positive supply voltage of analog circuits.
Form fields when the data on the card’s internal
power supply voltage measurements flag is ON (diagnostic values).
Negative supply voltage of the analog circuits.
Form fields when the data on the card’s
internal power supply voltage measurements flag is ON (diagnostic values).
Voltage measured on the battery B1 (NOT rechargeable battery).
Fields when the data on the
card’s internal power supply voltage measurements flag is ON (diagnostic values).
Voltage measured on the battery B2 (or rechargeable battery).
Form
fields when the
data on the card’s internal power supply voltage measurements flag is ON (diagnostic values).
% Battery charge.
Form fields when the data on the card’s internal power supply voltage
measurements flag is ON (diagnostic values).