MAN_MV110_EN_IT_IS_R13_1.04.XXXX
20 / 89
0-1.5V
3-40V
Block Totalizers
Totalizers Active
3-40V
0-1.5V
T
Reset
Tmin=100ms
Block
0-1.5V
3-40V
Scale 2
Scale 1
<18v
18-30V
Measure blocked
Measure
10KΩ
3-40Vdc (ON)
0/1.5Vdc (OFF)
15(+)
16(+)
10KΩ
16
22
10KΩ
15
21
+24
-0
3-40V
0-1.5V
T
Start/Stop
T > Measure min. time
DIGITAL INPUT ON/OFF OPERATION
POS. 6.1 see page 34 (T+; total direct positive set on)
POS. 6.2 see page 34 (P+; partial direct positive set on)
POS. 6.3 see page 34 (T-; total direct negative set on)
POS. 6.4 see page 34 (P-; total direct negative set on)
EXTERNAL POWER SUPPLY
INTERNAL POWER SUPPLY
BLOCK TOTALIZERS
RANGE CHANGE
MEASURE LOCK
RESET TOTALIZERS
SAMPLE RATE
Tmin
10HZ
220ms
20HZ
110ms
50HZ
45ms
MUST BE
T > Tmin
Necessary conditions for enabling the function
Necessary conditions for enabling the function
POS. 6.5 see page 34 (Totalizer counting lock command set on)
Necessary conditions for enabling the function
POS. 6.8 see page 34 (Range change set on)
Necessary conditions for enabling the function
POS. 6.6 see page 34 (Totalizer counting lock command set on)