MENU 10 - DATA LOGGER
The following functions are activated by [D.loger en= ON]
This function enables data logger.
Unit of measure recording enable
This function will set the separator character between data logger data.
Sampling interval. This function set the log frequency. [Interv.= Hours : Minutes: Seconds]
Enable logging of total direct totalizer.
Enable logging of partial direct totalizer.
Enable logging of total reverse totalizer
Enable logging of part
ial reverse totalizer
Enable logging of total net totalizer
Enable logging of partial net totalizer
Enable logging of flow rate in unit of measure
Enable recording of the flow rate as a percentage of full scale value set.
Enable logging of alarm events
(POS. 10.1) Data LOGger Enable
[D.logger en= /OFF]
AL3
[DLOGE]
(POS. 10.2) Data Logger Units of Measure Enable
[Meas. units= ON]
AL3
[DLUME]
(POS. 10.3) Data Logger Field Separator Character
[Field separ.= ;]
AL3
[DLFSC]
(POS. 10.5) Data LoGger Sample Interval
[Interv.= xx:xx:xx]
AL3
[DLGSI]
(POS. 10.6) Data logger Totalizer Total Positive Enable
[Log T+= ON
]
AL3
[DTTPE]
(POS. 10.7) Data logger Totalizer Partial Positive Enable
[Log P+= ON]
AL3
[DTPPE]
(POS. 10.8) Data logger Totalizer Total Negative Enable
[Log T-= ON]
AL3
[DTTNE]
(POS. 10.9) Data logger Totalizer Partial Negative Enable
[Log P-= ON]
AL3
[DTPNE]
(POS. 10.10) Data Logger totalizer Total Net Enable
[Log TN= ON]
AL3
[DLTNE]
(POS. 10.11) Data Logger totalizer Partial Net Enable
[Log PN= ON]
AL3
[DLPNE]
(POS. 10.12) Data logger Flow rate in Technical Units Enable
[Log Q(UM)= ON]
AL3
[DFTUE]
(POS. 10.13) Data logger Flow rate in PerCentage Enable
[Log Q(%)= ON]
AL3
[DFPCE]
(POS. 10.14) Data logger ALarm Events Enable
[Log AL.EV= ON]
AL3
[DALEE]
This function will set the separator character between data logger number value.
(POS. 10.4) Data Logger Decimal Separator Character
[Decim.separ.= .]
AL3
[DLDSC]