40 / 89
Lenght of cable between sensor and converter on separate version.
Derivative constant of coils current regulator. This function is activated if the sensor model is NOT present on the
sensors table standard parameters
Measure sampling frequency. This function is activated if the sensor model is NOT present on the sensors table
standard parameters
Enables the empty pipe detection function. This function is useful to keep the meter lock to zero when the pipe become
empty.
This function is useful to keep the electrodes clean; the allowed values are: OFF, minimum, average and maximum. It is
not recommended to use this function when the liquid has a conductivity less than 100µS/cm (set to OFF).
Proportional band of coils current regulator.This function is activated if the sensor model is NOT present on the sensors
table standard parameters
Excitation coils current. This function is activated if the sensor model is NOT present on the sensors table standard
parameters
Maximum resistance value at the inputs (electrodes) determine the empty pipe condition. This feature is enabled only if
the
"13.1" page37 Empty Pipe Detection is ON.
Calibration Factor. This function is activated if the sensor model is NOT present on the sensors table standard
parameters
This function enable/disable the presence of the preamplifier. The use of the preamplifier inhibit the possibility to use BIV
and Empty Pipe Detection.
(POS. 1.18) Preamplifier INstalled
[Preamplif.= ON]
AL4
[PREIN]
(POS. 1.14) CoeFFicient
KC
[KC= +/- xx.xxx]
AL4
[CFFKC]
(POS. 1.17)
Coils Regulator DERivative constant
[C.Reg. DK = xxx]
AL4
[CRDER]
(POS. 1.19)
Sampling FREQuency
[S.Freq.= Hz xx]
AL4
[SFREQ]
(POS. 1.20)
Empty Pipe Detection ENable
[E.P.Detect= ON]
AL3
[EPDEN]
(POS. 1.16)
Coils Regulator PRoportional Band
[C.Reg.PB= xxx]
AL4
[CRPRB]
(POS. 1.15)
Coils EXCitation Current
[C.Curr.= mA xxx.x]
AL4
[CEXCC]
(POS. 1.21)
Empty Pipe Detection THreshold
[Z max= Kohm xxxx]
AL4
[EPDTH]
(POS. 1.22) ELectrodes CLeaNing
[El.cleaning=OFF]
AL4
[ELCLN]
(POS. 1.23) Sensor CAble length Unit of Measure
[S.cable=m xxx]
AL4
[SCALN]