Goodrive200 inverters Function codes
100
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
3
on
model
P08.03
DEC time
3
Depend
on
model
○
P08.04
ACC time
4
Depend
on
model
○
P08.05
DEC time
4
Depend
on
model
○
P08.06
Jogging
frequency
This parameter is used to define the reference
frequency during jogging.
Setting range: 0.00Hz ~P00.03
(the Max. frequency)
5.00Hz
○
P08.07
Jogging
ACC time
The jogging ACC time means the time needed if
the inverter runs from 0Hz to the Max.
Frequency.
The jogging DEC time means the time needed if
the inverter goes from the Max. Frequency
(P0.03) to 0Hz.
Setting range:0.0~3600.0s
Depend
on
model
○
P08.08
Jogging
DEC time
Depend
on
model
○
P08.09
Jumping
frequency
1
When the set frequency is in the range of
jumping frequency, the inverter will run at the
edge of the jumping frequency.
The inverter can avoid the mechanical resonance
point by setting the jumping frequency. The
inverter can set three jumping frequency. But this
function will be invalid if all jumping points are 0.
0.00Hz
○
P08.10
Jumping
frequency
range 1
0.00Hz
○
P08.11
Jumping
frequency
2
0.00Hz
○
Содержание GD200-037G/045P-4
Страница 1: ...Goodrive 200 Inverter ...
Страница 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Страница 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Страница 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Страница 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Страница 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Страница 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Страница 245: ...Goodrive200 inverters Appendix B 244 B 3 Inverter chart B 4 Inverter chart B 4 1 Wall mounting 1 5 30kW wall mounting ...
Страница 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...