Goodrive200 inverters Function codes
60
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
inverter is in a stand-by state and wait for the
delay time set by P01.23
Setting range: 0.0~60.0s
P01.24
Delay time
of the stop
speed
Setting range: 0.0~100.0 s
0.0s
●
P01.25
0Hz output
selection
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
0
●
P02 Group Motor 1
P02.00
Reserved
◎
P02.01
Rated
power of
AM 1
0.1~3000.0kW
Depend
on
model
◎
P02.02
Rated
frequency
of AM 1
0.01Hz~P00.03(the Max. frequency)
50.00
Hz
◎
P02.03
Rated
speed of
AM 1
1~36000rpm
Depend
on
model
◎
P02.04
Rated
voltage of
AM 1
0~1200V
Depend
on
model
◎
P02.05
Rated
current of
AM 1
0.8~6000.0A
Depend
on
model
◎
Содержание GD200-037G/045P-4
Страница 1: ...Goodrive 200 Inverter ...
Страница 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Страница 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Страница 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Страница 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Страница 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Страница 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Страница 245: ...Goodrive200 inverters Appendix B 244 B 3 Inverter chart B 4 Inverter chart B 4 1 Wall mounting 1 5 30kW wall mounting ...
Страница 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...