Function
code
Name
Detailed instruction of parameters
Default
value
Modify
displayed. Unless input right password, the
operator can not enter into it.
Note:
Restoring to the default value can clear the
password, please use it with caution.
P07.01
Parameter
copy
The function code determines the mode of
parameters copy.
0:No operation
1:Upload the local function parameter to the
keypad
2:Download the keypad function parameter to
local address(including the motor parameters)
3:Download the keypad function parameter to
local address (excluding the motor parameter of
P02 group)
4:Download the keypad function parameters to
local address (only for the motor parameter of
P02 group)
Note:
After completing the 1~4 operation, the
parameter will come back to 0 automatically, the
function of upload and download excludes the
factory parameters of P29.
0
◎
P07.02
QUICK/JO
G function
selection
0:No function
1: Jogging. Press QUICK/JOG to begin the
jogging running.
2: Shift the display state by the shifting key.
Press QUICK/JOGto shift the displayed function
code from right to left.
3: Shift between forward rotations and reverse
rotations. Press QUICK/JOG to shift the direction
of the frequency commands. This function is only
valid in the keypad commands channels.
1
◎
Содержание GD200-037G/045P-4
Страница 1: ...Goodrive 200 Inverter ...
Страница 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Страница 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Страница 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Страница 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Страница 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Страница 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Страница 245: ...Goodrive200 inverters Appendix B 244 B 3 Inverter chart B 4 Inverter chart B 4 1 Wall mounting 1 5 30kW wall mounting ...
Страница 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...