First Start-up of Geared (Induction) Motors.
www.InvertekDrives.com
11.
First Start-up of Geared (Induction) Motors.
The below procedure illustrates a method for commissioning the OPTIDRIVE P2 ELEVATOR drive in a typical elevator application, it is assumed
the drive has already been mechanically installed.
Step 1- Wiring Connections.
The below diagram provides guidance for the wiring connections.
More technical information on the electrical wiring is available in section 6 and section 18 “Technical Data”.
Before making any wiring connections ensure that all voltage/power sources are isolated.
Step 1- Wiring Connection diagram.
Optidrive
Elevator
L3
L2
L1
3 Phase mains input.
U
V
W
Motor
Contactors
L1 L2 L3
U V W
+
Br
Braking
Resistor
+24Vdc
High Spd
Inspection spd
Up
Dn
1
4
6
2
3
Drive Inhibit(*)
12
(STO)
13
7
24Vdc Output (Drive Healthy)
Motor Contactor command
Motor Brake command
Control
Terminals
(A)
0V for 24Vdc outputs
24Vdc Output (Drive Enabled)
8
9
14
15
17
18
Relay 1
Relay 2
11
Control
Terminals
(B)
Cable screening/Shield
For Guidance on cable screening/shielding see section 6.1 “Installation in accordance with Good EMC Practice”
Drive Inhibit (*)
From a fast relay connected downstream of the safety chain.
Control Terminals (A)
Default configuration shown, for other configurations see section 6.10.1”
Control Terminals (B)
Default status sources shown for digital outputs (terminal 8 and 11), for other status sources see parameters P2-11
(terminal 8 function) and P2-13
Encoder Module
For 5V TTL Encoder use OPT-2-ENCOD-IN encoder module.
For 12-24V HTL Encoder use OPT-2-ENCHT-IN encoder module.
If Encoder does not have complimentary signals then connect as
shown opposite >.
Braking Resistor
Ensure braking resistor resistance is higher than minimum allowable value for the given drive rating, see section 18.3.
10kΩ