Optidrive P2 Elevator User Guide V2.30
Parameters
www.InvertekDrives.com
Group 8 and Group 9:
Refer to Optitools studio commissioning tool.
Parameter Group 0 –
Monitoring Parameters (Read Only)
Par
Description
Units
P0-01
Analog Input 1 Applied Signal Level
%
Displays the signal level applied to analog input 1 (Terminal 6) after scaling and offsets have been applied.
P0-02
Analog Input 2 Applied Signal Level
%
Displays the signal level applied to analog input 2 (Terminal 10) after scaling and offsets have been applied.
P0-03
Digital Input Status
-
Displays the status of the drive inputs, starting with the left hand side digit = Digital Input 1 etc.
P0-04
Pre Ramp Speed Controller Reference
Hz
Displays the set point reference input applied to the drive internal speed controller
P0-05
Torque Controller Reference
%
Displays the set point reference input applied to the drive internal torque controller
P0-06
Digital Speed Reference (Motorised Pot)
Hz
Displays the value of the drive internal Motorised Pot (used for keypad) speed reference
P0-07
Fieldbus Communication Speed Reference
Hz
Displays the setpoint being received by the drive from the currently active Fieldbus interface.
P0-08
PID Reference (Setpoint)
%
Displays the setpoint input to the PID controller.
P0-09
PID Feedback Level
%
Displays the Feedback input signal to the PID controller
P0-10
PID Controller Output
%
Displays the output level of the PID controller
P0-11
Applied Motor Voltage
V
Displays the instantaneous output voltage from the drive to the motor
P0-12
Output Torque
%
Displays the instantaneous output torque level produced by the motor
P0-13
Trip History Log
-
Displays the last four fault codes for the drive. Refer to section 19.1 for further information
P0-14
Motor Magnetising Current (Id)
A
Displays the motor magnetising Current, providing an auto tune has been successfully completed.
P0-15
Motor Rotor Current (Iq)
A
Displays the motor Rotor (torque producing) current, providing an auto tune has been successfully completed.
P0-16
DC Bus Voltage Ripple Level
V
Displays the level of ripple present on the DC Bus Voltage. This parameter is used by the Optidrive P2 Elevator drive for various
internal protection and monitoring functions.
P0-17
Motor Stator resistance (Rs)
Ω
Displays the measured motor stator resistance, providing an auto tune has been successfully completed.
P0-18
Motor Stator Inductance (Ls)
H
Displays the measured motor stator inductance, providing an auto tune has been successfully completed.
P0-19
Motor Rotor Resistance (Rr)
Ohms
Displays the measured motor rotor resistance, providing an auto tune has been successfully completed.
P0-20
DC Bus Voltage
V
Displays the instantaneous DC Bus Voltage internally within the drive
P0-21
Drive Temperature
°C
Displays the Instantaneous Heatsink Temperature measured by the drive
P0-22
Time Remaining to next service
V
Displays the number of hours remaining on the service time counter before the next service is due.
P0-23
Operating Time Accumulated With Heatsink Temperature Above 85°C
HH:MM:SS
Displays the amount of time in hours and minutes that the Optidrive P2 Elevator drive has operated for during its lifetime with a
heatsink temperature in excess of 80°C. This parameter is used by the Optidrive P2 Elevator drive for various internal protection and
monitoring functions.
P0-24
Operating Time Accumulated With Ambient Temperature Above 80°C
HH:MM:SS
Displays the amount of time in hours and minutes that the Optidrive P2 Elevator drive has operated for during its lifetime with an
ambient temperature in excess of 80°C. This parameter is used by the Optidrive P2 Elevator drive for various internal protection and
monitoring functions.
P0-25
Rotor Speed (Estimated or Measured)
-
In Vector control mode, this parameter displays either the estimated rotor speed of the motor, if no encoder feedback is present, or
the measured rotor speed if an optional Encoder Feedback Interface Option is fitted.