![Invertek Drives ODL-2-22010-1HF42-SN Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/invertek-drives/odl-2-22010-1hf42-sn/odl-2-22010-1hf42-sn_installation-and-operating-instructions-manual_2085070029.webp)
Optidrive P2 Elevator User Guide V2.30
29
Managing the Keypad
www.InvertekDrives.com
Resetting Parameters to Factory Default Settings
LED Display
Press and hold the
Keys for at least 2
seconds
The display will show
Press the
key
Resetting Parameters to User Default Settings
The current parameter settings of the drive can be stored internally within the drive as the standard default settings. This does not affect the
procedure for returning the drive to factory default settings as described above.
P6-29 (Save user parameters as default) can be enabled (set to 1) to invoke a parameter save of the current parameter values as the standard
defaults for the drive. Parameter menu group 6 can only be accessed with advanced security level access (Default P1-14=201).
Load default parameters
STOP
U-DEF
37kW
400V
3Ph Press STOP key to Reset
Hold down the Up, Down, Start
and Stop keys for >2s
The display shows P-Def. Drive is
returned to factory settings. Press
the Stop key
Note: Parameters cannot be defaulted whilst P2-39=1 (parameter set locked).
Elevator Specific Linear Units
The drive provides the user with the option to program the drive and view the elevator speed in real time in elevator units e.g. m/s, the drive
calculates the value internally providing the correct values are entered into the below parameters.
To enable this feature the user must program the following parameters:
Motor Rated Speed (P1-10)
Sheave Diameter (P3-15) (<100 drive assumes inches)/(>100 drive assumes mm)
Roping Ratio (P3-16)
Gear Ratio for Geared (Induction) systems (P3-17)
Note: If P1-10 and P3-15 are zero then the function is inactive.
Once the above parameters are programmed the user can view the real time travel speed by pressing the
(navigate button) until “r“ is
shown in the left side of the display, this is further detailed in section 9.1.