Optidrive P2 Elevator User Guide V2.30
9
Mechanical Installation
www.InvertekDrives.com
5.
Mechanical Installation
General
The Optidrive P2 Elevator drive should be mounted in a vertical position only, on a flat, flame resistant, vibration free mounting using
the integral mounting holes or DIN Rail clip (Frame Size 2 only).
The Optidrive P2 Elevator drive must be installed in a pollution degree 1 or 2 environment only.
Do not mount flammable material close to the Optidrive P2 Elevator drive.
Ensure that the minimum cooling air gaps, as detailed in section 5.5 and 5.8 are left clear
Ensure that the ambient temperature range does not exceed the permissible limits for the Optidrive P2 Elevator drive given in
section 18.1
Provide suitable clean, moisture and contaminant free cooling air sufficient to fulfil the cooling requirements of the Optidrive P2
Elevator drive.
Before Installation check the drive rating label to ensure it is of the correct type and power requirements for the application.
Carefully Unpack the Optidrive P2 Elevator drive and check for any signs of damage. Notify the shipper immediately if any exist.
Store the Optidrive P2 Elevator drive in its original box until required. Storage should be clean and dry and within the temperature
range –40°C to +60°C
Routine Maintenance
The drive should be included within the scheduled maintenance program so that the installation maintains a suitable operating
environment, this should include:
Ambient temperature is within the temperature range as set out in the “Environmental” section 18.1.
Heat sink fans freely rotating and dust free.
The Enclosure in which the drive is installed should be free from dust and condensation; furthermore ventilation fans and air filters
should be checked for correct air flow.
Checks should also be made on all electrical connections, ensuring screw terminals are correctly torqued; and that power cables have no signs
of heat damage.
UL Compliant Installation
Note the following for UL-compliant installation:
The drive can be operated within an ambient temperature range as stated in section 18.1
For IP20 units, installation is required in a pollution degree 1 environment
For IP55 units, installation in a pollution degree 2 environment is permissible
UL Listed ring terminals / lugs must be used for all bus bar and grounding connections
Mechanical dimensions and weights (IP20 Units)
Drive
Size
A
B
C
D
E
F
Weight
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
Kg
lb
2
221 8.70 110 4.33 185 7.28 209 8.23
63
2.48
63
2.48
1.8
4.0
3
261 10.28 131 5.16 205 8.07 247 9.72
80
3.15
80
3.15
3.5
7.7
4
418 16.46 160 6.30 240 9.45 400 15.75 125 4.92 125 4.92
9.2 20.3
5
486 19.13 222 8.74 260 10.24 460 18.11 175 6.89 175 6.89 18.1 39.9
Mounting Bolts
Tightening Torques
Frame Size
Metric
UNF
Frame
Size
Required Torque
2
M4
#8
Control Terminals
All
0.5 Nm
4.5 lb-in
3
M4
#8
Power Terminals
2 & 3
1 Nm
9 lb-in
4
M8
5/16
4
2 Nm
18 lb-in
5
M8
5/16
5
4 Nm
35.5 lb-in