32
INSTALLATION AND ASSEMBLY
aV100 extract air system – Avio N 100
•
Installation and operating instructions
5.7
Install the aV100 extract air system with flat duct and reveal grille
(corner model)
Installing the wall sleeve for flat duct and reveal grille
Requirements:
The power cable has been laid.
TIP
Before inserting the wall sleeve, rotate the fixing elements upwards.
NOTE
Algae accumulation around the flat duct.
Discolouration of the facade!
► Secure all sealing tapes circumferentially before installing the flat duct.
► In vulnerable areas, apply a biocidal/water repellent treatment to the masonry around the flat
duct before installing.(Consult your planner about this!)
►
Turn the fixing elements (2) on the
wall sleeve (1) upwards 90°.
1
2
►
Attach the sealing tape, 9 mm (4)
circumferentially to the sleeve (3) of the wall
sleeve.
Be sure to
leave a distance of 8 mm between
the outer edge of the wall sleeve and the
sealing tape.
8
3
4