38
INSTALLATION AND ASSEMBLY
aV100 extract air system – Avio N 100
•
Installation and operating instructions
Install the reveal grille
Requirements:
The exterior wall is completed and even.
The adhesive tape on the flat duct's opening has been removed.
NOTE
Install on unfinished exterior wall.
Damage to the exterior wall!
►
Do not install the reveal grille until the exterior wall is completed and fully cured.
NOTE
Algae accumulation around the reveal grille.
Discolouration of the facade!
►
In vulnerable areas, apply a biocidal/water repellent treatment to the plaster surface around
the reveal grille before installing. (Consult your planner about this!)
Ö
Ö
The reveal grille is installed.
5.8
Insert Avio N 100 extractor fan and connect power cable
DANGER
Exposed electrical components.
Electric shock and injury due to live components (230V, 50Hz)!
►
Before working on electrical installations, disconnect all affected equipment from the power
supply.
TIP
Mounting the extractor fan is shown below when mounting the extractor fan directly into the wall
sleeve.
When mounting the extractor fan subceiling.
Additionaly on the subceiling a 105 mm diameter hole for the fan must be cut. The power cable
must be laid (only when mounting subceiling!) between ceiling and subceiling to the hole for the
fan instead of the wall sleeve. The connection between wall sleeve and extractor fan must be
carried out on site.
►
Place the reveal grille (2) on the sliding sleeve
(1).
Ensure that
the blades (3) of the reveal
grille (2) direct the air flow away from the
window.
►
Push the reveal grille (2) onto the sliding
sleeve (1).
Ensure that
the reveal grille clicks into place.
2
1
3