SPECIFICATIONS
aV100 extract air system – Avio N 100
•
Installation and operating instructions
7
Specifications
Extract air system operating conditions
Feature
Value
Ambient temperature
5°C – 40°C
Supply air
Free from aggressive gases, dust and oils
Air flow characteristic of Avio N 100 extractor fan
Figure 24:
Air flow performance of Avio N 100 extractor fan:
Extractor fan with run-on function (Avio N 100)
Feature
Value
Protection class
II
Type of protection
IP44
Input voltage
AC 230 V, 50 Hz
Power consumption
6.4 W
Width x Height x Depth
159 x 159 x 115
Weight
590 g
Noise emission (rated)
28 dB(A)
Run-on time
5 minutes – 30 minutes