Chapter 2 — Using the PA30 in an Applicator
46
PA30 Print Engine User’s Manual
Cause:
Application sent the Fingerprint command
PORTOUT(PORT)
ON|OFF
on a port used by the applicator port when the applicator
port is enabled.
Error Number:
89
ERRINPUTON
Message:
Operation not allowed in Direct Protocol.
Cause:
Running the
PORTOUT.DATAREADY ON|OFF
or
PORTIN.<SIGNAL> GOSUB
XXX
commands when the PA30 is
using Direct Protocol.
Error Number:
90
EAPPERR1
Message:
Applicator Error 1.
Cause:
AppErr1 in signal detected.
Result:
Activates event in System Health Monitor (SHM).
Error Number:
1340
EAPPERR2
Message:
Applicator Error 2.
Cause:
AppErr2 in signal detected.
Result:
Activates event in System Health Monitor (SHM).
Error Number:
1341
EAPPERR3
Message:
Applicator Error 3.
Cause:
AppErr3 in signal detected.
Result:
Activates event in System Health Monitor (SHM).
Error Number:
1342
ERTWINEXT
Message:
RTW Extenal Error.
Cause:
RTWExternal in signal detected.
Result:
Activates event in System Health Monitor (SHM).
Error Number:
1343
ENODATAREADY
Message:
Dataready not enabled.