Chapter 2 — Using the PA30 in an Applicator
PA30 Print Engine User’s Manual
37
About PA30 In Signals
This section describes the PA30 in signals.
Startprint
Starts a print job. Choose either:
• Level: The PA30 starts printing labels when the startprint
signal is asserted, and continues printing until the signal is de-
asserted.
• Pulse: The PA30 prints one label when the startprint signal is
asserted. The startprint signal must be de-asserted and then
asserted to print the next label.
Feed
Feeds a single label. Not supported by S-Style.
Out Signals
Shows the current state of the 8 out signals, from left
(lowest numbered port) to right. 0 indicates low, 1
indicates high.
Note:
Out signals can only be configured in Setup
Mode.
For more information, see
“About PA30 Out Signals”
on page 38.
Relay Signals
(Read-only)
Shows the current state of the four relay signals, from
left (lowest numbered port) to right. 0 indicates low, 1
indicates high.
On the applicator interface, the relay signals determine
whether an internal or external power source is used.
When the applicator port is disabled, use the
Fingerprint PORTOUT(PORT) command to
configure the power source.
Error on
Pause
Enable this setting to set the “service required” signal
when the PA30 is paused.
This setting is supported by Z-Style only.
Error Port
Enables or disables the PA30 External Error port.
Applicator Port Settings Descriptions (continued)
Setting
Description
Note:
All in signals are asserted low and de-asserted high.