48
Identifying Management Menu Options
The Management menu options are as follows:
Option
Description
Configure
Configures physical arrays and logical drives
Initialize
Initializes one or more logical drives
Objects
Individually accesses controllers, logical drives, physical drives and
SCSI channel settings
Format
Low-level formats a hard disk drive
Rebuild
Rebuilds a failed disk drive
Check
Consistency
Verifies that the redundancy data is correct in logical drives using
RAID level 1, 3, or 5
Select Adapter
Selects a MegaRAID host adapter (controller)
Disable BIOS
Disables the BIOS
The following table defines some terms you will see while configuring drives and running
the MegaRAID BIOS configuration utility.
READY
Disk drive ready for configuration
ONLINE
Disk drive ready for use
REBUILD
Disk drive in rebuild state
OFFLINE
Unformatted drive
PACK
Configured pack
DRIVES
Number of drives in a pack
SIZE
Size of the packs (in megabytes)
HOTSP
Disk drive configured as hotspare (standby) drive
FAIL
Disk drive in fail state
Exiting MegaRAID BIOS
To exit the MegaRAID BIOS configuration utility, press
ESC
while the Management menu
displays. Choose Yes at the prompt to save changes and exit. You must then reboot the
system. The MegaRAID BIOS message displays again. Press
ESC
when the BIOS
Configuration Utility prompt displays.