131
NOTE
If you must remove the top power supply from bay 3, do so as described above and store the
power supply in a static protective package.
6. Replace the power supply cover or close the cooling fan panel. Lift the latch located at
the bottom of the cooling fan panel to release the cooling fan panel, allowing it to close.
7. Using the packaging materials from the replacement power supply, repackage the failed
power supply and return it to Intergraph Computer Systems. Refer to “Returning
Equipment to Intergraph Computer Systems” in Chapter 1.
Replacing Cooling Fans
The InterRAID-8e has hot-swap cooling fans. You do not have to turn off power to the
InterRAID-8e cabinet to replace the cooling fans.
To replace a cooling fan:
1. Locate the failed cooling fan at the back of the cabinet. The failed cooling fan will not
be running .
2. Using a slotted screwdriver, loosen the two screws holding the failed cooling fan panel
to the back of the cabinet, and then open the panel .
3. Disconnect the in-line connector of the power cable for the failed fan.
Power Cable for
Fan 1
Power Cable for
Fan 2
Cooling
Fan Panel
In-line
Connector