40
Options Menu
The Options Menu displays the following selections.
u
SCSI ID
u
Heat Threshold
u
SAF-TE Chain ID
u
Change Passcode
u
Lock (or Unlock)
SCSI ID
SCSI ID displays the ID that is set for each disk drive slot. Intergraph Computer Systems
recommends that you do not change any SCSI ID settings, even though SCSI IDs 0 through
15 are available and can be changed at the SCSI ID menu. If you change a SCSI ID setting,
you must turn off power to the InterRAID-8e cabinet and wait 30 seconds before turning on
power again for those settings to take effect. Be sure to turn off the power to the system base
unit before you turn off power to the InterRAID-8e cabinet.
NOTE
If you turn off the power to the InterRAID-8e cabinet and then power off the system base unit,
the RAID controller will mark offline all drives in the array.
Set Upper and Lower Slot IDs
NOTE
Disk drive SCSI IDs cannot be set individually with these menu selections.
Intergraph Computer Systems recommends that you do not change the SCSI ID settings. If
necessary, you can set SCSI IDs manually for each group of slots from a pre-defined table of
IDs. The currently set IDs will display on the ICP. Refer to the following example:
0
1
2
3
Lower 4
0
1
2
4
4
5
6
7
4
5
6
8
5
6
7
8
The IDs will be assigned sequentially beginning with the lowest slot in the group. Choose
“Set Lower Slot IDs” or “Set Upper Slot IDs” for the appropriate slots and press the
ENTER
key.