73
The rebuild types are as follows:
Type
Description
Automatic
Rebuild
MegaRAID automatically tries to use hotspares to rebuild failed disk
drives. Display the Objects menu, Physical Drive option screen while a
rebuild is in progress. The drive indicator for the hotspare disk drive
changes to REBLD A[array number]-[drive number], indicating the disk
drive to be replaced.
Manual
Rebuild
Manual rebuild is necessary if there are no hotspares with enough capacity
to rebuild the failed drives.
To rebuild an individual drive using manual rebuild:
1. Choose Objects from the Management menu. Choose Physical Drive from the Objects
menu. A device selection window displays showing the devices connected to the current
controller:
2. Press the arrow keys to highlight the physical drive to be rebuilt and press
ENTER
. The
following action menu displays:
3. Choose the Rebuild option from the action menu and respond to the confirmation
prompt. Rebuilding can take some time, depending on the drive capacity.
4. When rebuild completes, press any key to return to the previous menu.