Intel® Server System R2600SR Setup and Service Guide
50
USERID and the default password is PASSW0RD (zero, not an uppercase o)
<ip_address> is the IP address of the BMC.
b.
Alternatively, the following Advanced Settings Utility (ASU) commands can be used:
To enable secure boot:
asu64.exe set SecureBootConfiguration.SecureBootis Enabled -v --
override --host <ip_address>
--user <userid> --password <password>
To disable secure boot:
asu64.exe set SecureBootConfiguration.SecureBootis Disabled -v --
override --host <ip_address>
--user <userid> --password <password>
To read the secure boot setting:
asu64.exe show SecureBootConfiguration.SecureBootis -v --override --
host <ip_address>
--user <userid> --password <password>
where:
<userid> and <password> are the credentials used in the BMC of the server. The default user ID is
USERID and the default password is PASSW0RD (zero, not an uppercase o)
<ip_address> is the IP address of the BMC.
3.12
Replacing System Fans
The system includes five hot-swap fans which are used to cool all components.
The five system fans have the following specifications:
Three 60mm x 60mm x 56mm hot-swap fans
Two 80mm x 80mm x 80mm hot-swap fans
CAUTION: To minimize possible performance degradation and other thermal-related issues, replace a
system fan as quickly as possible while the system is operational. System fans operate at very high speeds.
Keep all tools and fingers away from all system fans when swapping out a defective fan. Components within
an operational system can get very hot. Avoid touching any components within the system while swapping
out a defective system fan.